2021
DOI: 10.1016/j.ijheatmasstransfer.2021.121102
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of parameters for air dehumidification systems including multilayer fixed-bed binder-free desiccant dehumidifier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…However, the heat and mass transfer performance of the system was affected not only by the overall thermal resistance, but by the thermal resistance between the evaporator and vessel wall, so the device needed to be further optimized. Yu et al [31] reduced the impact of adsorption heat by adding water heating and cooling devices to the multi-layer fixed bed non binder dehumidifier to improve the dehumidification efficiency of the system, as shown in Figure 2e. Under the conditions of T=27 ℃, v=0.9 m/s and w 0 =10.01 g/kg and 14.88 g/kg respectively, the maximum dehumidification efficiency of the dehumidifier was 24% and 33% higher than that of the traditional fixed bed.…”
Section: Single Materials Packed Bedmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the heat and mass transfer performance of the system was affected not only by the overall thermal resistance, but by the thermal resistance between the evaporator and vessel wall, so the device needed to be further optimized. Yu et al [31] reduced the impact of adsorption heat by adding water heating and cooling devices to the multi-layer fixed bed non binder dehumidifier to improve the dehumidification efficiency of the system, as shown in Figure 2e. Under the conditions of T=27 ℃, v=0.9 m/s and w 0 =10.01 g/kg and 14.88 g/kg respectively, the maximum dehumidification efficiency of the dehumidifier was 24% and 33% higher than that of the traditional fixed bed.…”
Section: Single Materials Packed Bedmentioning
confidence: 99%
“…Figure 2: (a) Intercooling packed bed[17], (b) Cooling packed bed[28], (c) Internal cooling solid desiccant bed[29], (d) Schematic of the three HCOHPs integrated with the packed bed[30], (e) Schematic diagram of air dehumidification system[31], (f) Structure diagram of fixed bed with water pipes[32].…”
mentioning
confidence: 99%
“…Yu et al [27] proposed to add to the Shamim configuration [26] a water cooling and heating cycle. The authors performed digital simulation for this new proposed configuration for calculating any transient transfer of heat and mass, as well as optimizing all parameters.…”
mentioning
confidence: 99%