2007
DOI: 10.1007/s00340-007-2744-1
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of frequency modulation transfer spectroscopy on the calcium 41 S 0 to 41 P 1 transition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
18
0
1

Year Published

2009
2009
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(19 citation statements)
references
References 15 publications
0
18
0
1
Order By: Relevance
“…This spectroscopy mode yields spectra without the Doppler background and free of etalon offsets, but the spectra otherwise resemble FM spectra showing all transitions and crossovers, and the usable servo bandwidth is less than 10 kHz. Recent work has revived interest in MTS-based laser locking, in particular due to the clean spectra and wide control bandwidths made possible by MTS at high modulation frequencies [8,9]. These workers used resonant electro-optical modulators (EOMs) to phase modulate the pump beam at high modulation frequencies above 1 MHz.…”
Section: Introductionmentioning
confidence: 99%
“…This spectroscopy mode yields spectra without the Doppler background and free of etalon offsets, but the spectra otherwise resemble FM spectra showing all transitions and crossovers, and the usable servo bandwidth is less than 10 kHz. Recent work has revived interest in MTS-based laser locking, in particular due to the clean spectra and wide control bandwidths made possible by MTS at high modulation frequencies [8,9]. These workers used resonant electro-optical modulators (EOMs) to phase modulate the pump beam at high modulation frequencies above 1 MHz.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the frequency stabilization of the cooling laser becomes very important. Some frequency-locking schemes for this kind of atoms have been demonstrated [5][6][7].…”
Section: Introductionmentioning
confidence: 98%
“…В работах [9][10][11][12][13] показано, что наклон сигнала ошибки существенно зависит от пара-метров гармонической частотной модуляции (индекса и * X Международная конференция молодых ученых и специалистов " Оптика 2017", 16-20 октября 2017 г., Санкт-Петербург, Россия частоты модуляции), используемой в системах стабили-зации. Данный наклон является одним из основных пара-метров, определяющих метрологические характеристики (стабильность и точность) частотных стандартов [14].…”
Section: Introductionunclassified