1995
DOI: 10.1366/0003702953963986
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Excitation and Detection Geometry for Multiplexed Capillary Array Electrophoresis of DNA Fragments

Abstract: A new on-column excitation and detection geometry for multiplexed array capillary electrophoresis is evaluated. The detection limit is improved 100-fold for the same laser power because of more efficient coupling of the laser beam. The illumination is also more uniform over the entire array. Stray light and cross-talk are effectively suppressed by immersing the capillaries in water to roughly match the refractive index. A charge-coupled-device (CCD) camera combined with cutoff filters provides adequate sensiti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
28
0

Year Published

1998
1998
2000
2000

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 40 publications
(30 citation statements)
references
References 14 publications
2
28
0
Order By: Relevance
“…The possible regeneration of capillaries enhances their lifetime. The sensitivity of 1´10 ±11 M (S/N = 40), which can be extrapolated to a detection limit in the very low pM range at S/N = 2, is comparable to that achieved with fiber optic detection (3.7´10 ±12 M [14]), confocal scanning systems (2´10 ±12 M [27]), and to that achieved with camera detection and side illumination [20]. Only sheath flow systems were reported to have a lower detection limit (1´10 ±13 M [5]).…”
Section: Discussionsupporting
confidence: 52%
See 1 more Smart Citation
“…The possible regeneration of capillaries enhances their lifetime. The sensitivity of 1´10 ±11 M (S/N = 40), which can be extrapolated to a detection limit in the very low pM range at S/N = 2, is comparable to that achieved with fiber optic detection (3.7´10 ±12 M [14]), confocal scanning systems (2´10 ±12 M [27]), and to that achieved with camera detection and side illumination [20]. Only sheath flow systems were reported to have a lower detection limit (1´10 ±13 M [5]).…”
Section: Discussionsupporting
confidence: 52%
“…Axial illumination has been described [4], but a better possibility is to couple the light from the side into the capillary array [11,14,20], similar to the illumination principle used in some slab gel sequencers. However, this requires a carefully focused and adjusted laser beam.…”
Section: Illuminationmentioning
confidence: 99%
“…We [15] and other groups [14,16] have developed capillary-array systems that use both side-entry laser irradiation and on-column detection. In the original configuration of our system, all 24 capillaries were placed in air.…”
Section: Introductionmentioning
confidence: 99%
“…In all of the reports on multiplexed capillary electrophoresis for DNA sequencing [1,4,6], sample injection is carried out electrokinetically since gel-filled capillaries are employed to separate DNA fragments. Typically, the sample was injected from one vial to many (bundled) capillaries for evaluation.…”
Section: Introductionmentioning
confidence: 99%