2015
DOI: 10.1007/s10948-015-3165-8
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Distributive Ratios of Apportioned Winding Configuration in HTS Power Transformers for Hysteresis Loss and Leakage Flux Reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…The ability to continuously overload operation without degradation of insulation due to thermal stresses is another advantage of HTS transformers. Fault tolerant HTS transformers operate not only to regulate the voltage level but also to limit the fault current [30][31][32][33][34][35].…”
Section: Applications Of Scs and The Challengesmentioning
confidence: 99%
“…The ability to continuously overload operation without degradation of insulation due to thermal stresses is another advantage of HTS transformers. Fault tolerant HTS transformers operate not only to regulate the voltage level but also to limit the fault current [30][31][32][33][34][35].…”
Section: Applications Of Scs and The Challengesmentioning
confidence: 99%
“…Most of the Finite Element Methods (FEM) used for simulating superconductors including tapes, coils, and stacks (such as methods utilizing commercial software) employ boundary conditions at the external surface of the air domain. The air domain should be large enough (around 10 times bigger than the dimension of superconducting object) in order to obtain a precise solution, and hence it must be meshed [59], [60]. This adds a significant number of mesh elements to the solution and thus significant extra computing time.…”
Section: Introductionmentioning
confidence: 99%
“…As for Fujikura tape, three parameters, k = 0.71, B0 = 100 mT and = 0.23 are characteristics associated with magnetic field dependence of the materials [3].…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, it is very important for the design and industrialization of superconducting transformer to accurately Xu Liao, Jin Fang, Xin Zhao, Song Yang, Yueming Sun, Yue Wu are with calculate the AC loss of HTS transformer. Over the past decade, research groups have been designing, manufacturing and testing HTS transformers used in various fields [1][2][3][4]. Since 2018, Beijing jiaotong University has been leading a six-party cooperation project to develop a 6.5 MVA HTS traction transformer for high-speed trains.…”
Section: Introductionmentioning
confidence: 99%