1989
DOI: 10.1016/s0009-9120(89)80063-3
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of atrial natriuretic factor radioimmunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
29
0

Year Published

1990
1990
2017
2017

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 69 publications
(30 citation statements)
references
References 11 publications
1
29
0
Order By: Relevance
“…Urinary cGMP concentrations were determined with a commercially available RIA kit (Dupont-NEN, Boston, MA). Plasma and cardiac tissue concentrations of immunoreactive (ir) ANF and BNP were determined by RIA using anti-rat ANF99-126 and anti-rat BNP64-95 serum, respectively, from Peninsula Laboratories, Inc. (Belmont, CA) (38). The antibodies used showed less than 0.01% crossreactivity between ANF and BNP.…”
Section: Assay Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Urinary cGMP concentrations were determined with a commercially available RIA kit (Dupont-NEN, Boston, MA). Plasma and cardiac tissue concentrations of immunoreactive (ir) ANF and BNP were determined by RIA using anti-rat ANF99-126 and anti-rat BNP64-95 serum, respectively, from Peninsula Laboratories, Inc. (Belmont, CA) (38). The antibodies used showed less than 0.01% crossreactivity between ANF and BNP.…”
Section: Assay Methodsmentioning
confidence: 99%
“…After plasma processing, the cartridges were washed with 20 ml of 0.1% trifluoroacetic acid (38), and then eluted with 3 ml of 60% acetonitrile in 0.1% trifluoroacetic acid. Tissue samples were homogenized in 10 vol of an extracting mixture consisting of 0.1 N HCl, 1.0 M acetic acid, and 1% NaCl, and centrifuged at 10,000 g for 30 min at 40C.…”
Section: Extraction Ofplasma and Tissue Samplesmentioning
confidence: 99%
“…Upon thawing, plasma samples were acidified by addition 100 l 1.0 N HCl/ml plasma and extracted with Sep-Pak C 18 cartridges (Millipore-Waters, Milford, MA). Radioimmunoassay was performed using the double antibody technique as previously described by Sarda et al (30).…”
Section: Plasma Samplesmentioning
confidence: 99%
“…ANF levels were determined in 100-l aliquot media samples using the double antibody RIA technique, as described by Sarda et al (30). Antisera against ANF 99 -126 (Peninsula Laboratories) were used.…”
Section: Anf Radioimmunoassaymentioning
confidence: 99%
“…Standard competitive RIA was performed to quantify ANF according to a previously published protocol (43).…”
Section: Animalsmentioning
confidence: 99%