2011
DOI: 10.1016/j.chroma.2011.03.043
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of a novel method for determination of benzene, toluene, ethylbenzene, and xylenes in hair and waste water samples by carbon nanotubes reinforced sol–gel based hollow fiber solid phase microextraction and gas chromatography using factorial experimental design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(26 citation statements)
references
References 32 publications
0
26
0
Order By: Relevance
“…The injector and detector temperatures were set to 200ºC and 300ºC, respectively. The injection was undertaken in split mode with split ratios of 1:10 and 1:20 for the first 2 min and the remaining run time, respectively due to avoid of overlap or flatting of some peaks and prevent of probably leakage which may be new fiber has [12,[33][34][35]. Nitrogen (>99.999%) at a constant pressure of 4 psi was used as the carrier gas.…”
Section: Apparatusmentioning
confidence: 99%
“…The injector and detector temperatures were set to 200ºC and 300ºC, respectively. The injection was undertaken in split mode with split ratios of 1:10 and 1:20 for the first 2 min and the remaining run time, respectively due to avoid of overlap or flatting of some peaks and prevent of probably leakage which may be new fiber has [12,[33][34][35]. Nitrogen (>99.999%) at a constant pressure of 4 psi was used as the carrier gas.…”
Section: Apparatusmentioning
confidence: 99%
“…Blood samples were collected from the ocular vein in clean heparinized glass tubes before (0 h) and 0.033, 0.083, 0.17, 0.25, 0.5, 0.75, 1,2,4,6,8,9,12,24, and 36 h after dosing. The samples were then centrifuged and the separated plasma was processed as described above.…”
Section: Application In the Pharmacokinetic Studymentioning
confidence: 99%
“…The application of OAD can simplify the experimental procedure without affecting the quality of results. Adopted as a chemometric method, OAD has been widely used for the optimization of analytical procedures in recent years [20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…In situ fiber solid phase microextraction [1] (SPME) is a mature quantitative sampling technique that enables trace-level multianalyte detection for a wide range of sample matrices [2][3][4][5] and environmental conditions [6][7][8][9]. In fiber SPME, a syringe-like device houses a retractable fused silica fiber with an immobilized stationary extraction phase at its tip, which is inserted into the sample headspace or liquid to collect and concentrate analytes via absorption and/or adsorption, until ideally equilibrium is achieved.…”
Section: Introductionmentioning
confidence: 99%