2006
DOI: 10.1016/j.chroma.2006.04.038
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of a microwave-assisted extraction method for the analysis of polycyclic aromatic hydrocarbons from fish samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
35
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 79 publications
(41 citation statements)
references
References 16 publications
4
35
0
1
Order By: Relevance
“…Regarding the repeatability of the optimised methodology, ex-pressed as RSD, values were lower than 7%. The results obtained are in general agreement with other works that used the same SRM 2977 and applied different PAH extraction procedures devel-oped specially for bivalve mollusks (Fernández-González et al, 2010;Fuoco et al, 2005;Pena et al, 2006;Sanz-Landaluze et al, 2006;Veyrand et al, 2007;Yusà, Pardo, Martí, & Pastor, 2005). Fur-thermore, results are comparable or in line with those reached by Serpe et al (2010) that validated a complex sample preparation methodology involving alkaline digestion, liquid-liquid extraction and solid phase clean-up for determination of 11 PAHs in mussels by LC with fluorescence detection.…”
Section: Validation Of Microwave-assisted Extractionsupporting
confidence: 80%
See 3 more Smart Citations
“…Regarding the repeatability of the optimised methodology, ex-pressed as RSD, values were lower than 7%. The results obtained are in general agreement with other works that used the same SRM 2977 and applied different PAH extraction procedures devel-oped specially for bivalve mollusks (Fernández-González et al, 2010;Fuoco et al, 2005;Pena et al, 2006;Sanz-Landaluze et al, 2006;Veyrand et al, 2007;Yusà, Pardo, Martí, & Pastor, 2005). Fur-thermore, results are comparable or in line with those reached by Serpe et al (2010) that validated a complex sample preparation methodology involving alkaline digestion, liquid-liquid extraction and solid phase clean-up for determination of 11 PAHs in mussels by LC with fluorescence detection.…”
Section: Validation Of Microwave-assisted Extractionsupporting
confidence: 80%
“…The overall mean recoveries obtained at each level were 85.1 ± 8.9% for level I, 84.7 ± 9.5% for level II, 82.3 ± 9.3% for level III and 81.1 ± 9.8% for level IV. The reported results are in accor-dance with previous related studies (Akpambang et al, 2009;El-Saeid, 2006;Pena et al, 2006;Soclo et al, 2008). Pena et al (2006) Validation was also performed by using a certified reference material since spiked solid matrices are known to be more easily extractable than real environmental matrices.…”
Section: Validation Of Microwave-assisted Extractionsupporting
confidence: 64%
See 2 more Smart Citations
“…To increase the laboratory throughput and reduce the required workload, automated procedures enabling a short extraction time, such as supercritical fluid extraction (SFE) (Antunes & Bernardo-Gil 2003;Rodil et al 2005Rodil et al , 2007García-Rodríguez et al 2008), microwave assisted extraction (MAE) (Bayen et al 2004;Pena et al 2006;Barriada-Pereira et al 2008), and pressurised liquid extraction (PLE) (Suchan et al 2004;Liguori et al 2006;Losada et al 2009) have been reported in many studies. Moreover, the efficiency of PLE can be increased by the addition of a purification phase into the PLE cell which allows a pre-purification step resulting in a higher method selectivity (Björklund et al 2001;Gómez-Ariza et al 2002;Sporring & Björklund 2004;Lund et al 2009).…”
mentioning
confidence: 99%