2016
DOI: 10.1109/jsen.2016.2600272
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of a High-Frequency Current Transformer Sensor for Partial Discharge Detection Using Finite-Element Analysis

Abstract: Abstract-High Frequency Current Transformer (HFCT) sensors are widely used for Partial Discharge detection due to their versatility, high sensitivity and wide bandwidth. This paper reports on a Finite Element Analysis (FEA) methodology that can be employed to optimize HFCT performance. The FEA model consists of accurate 3D representations of the sensor components. Two different FEA software modules were used in order to cover the wide operating frequency range of the sensor. The simulation computes the frequen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(22 citation statements)
references
References 9 publications
0
19
0
Order By: Relevance
“…A 50 Ω RG-405 coaxial cable connects the plane electrode with a pre-installed high-pressure rated coaxial feedthrough. A coaxial cable connected to the low-pressure side of the feedthrough is then connected to the configuration shown in Figure 5, similar implementations of which were presented in [20,21]. Two SMA connectors are mounted on the top and bottom of a C101 alloy copper rod.…”
Section: Current Sensing and Recordingmentioning
confidence: 99%
“…A 50 Ω RG-405 coaxial cable connects the plane electrode with a pre-installed high-pressure rated coaxial feedthrough. A coaxial cable connected to the low-pressure side of the feedthrough is then connected to the configuration shown in Figure 5, similar implementations of which were presented in [20,21]. Two SMA connectors are mounted on the top and bottom of a C101 alloy copper rod.…”
Section: Current Sensing and Recordingmentioning
confidence: 99%
“…Demagnetization can be achieved by increasing the burden [64]. High-Frequency Current Transformers work up to 50 MHz [65].…”
Section: Current Transformers Rogowski Coils and Fluxgate Current Sementioning
confidence: 99%
“…In piezoelectricity, the quantities involved are tensors, despite some particular directions of the crystals, the vectors are in the same direction [24]. The relations of scalar quantities are given by (1) and (1), respectively:…”
Section: Piezoelectricity and Mfc Sensorsmentioning
confidence: 99%
“…P OWER Transformers are high-cost equipment and essential for the electrical system operation. During the operation of power transformers, some factors such as overload, nonlinear loads and switching can cause the degradation of the insulating system, which allows the occurrence of internal partial discharges [1]- [3]. Partial discharges (PD) are random phenomena which have a direct influence on the transformers failures as well as on the interruptions in the power system.…”
Section: Introductionmentioning