2014
DOI: 10.1016/j.brachy.2013.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Optimization for high-dose-rate brachytherapy of cervical cancer with adaptive simulated annealing and gradient descent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 20 publications
0
13
0
Order By: Relevance
“…Yao et al. explored the use of gEUD as an inverse optimization objective function 45. The D2cc EQD2 OAR values are used as OAR plan evaluation metrics based upon the recommendations of the GEC‐ESTRO working group,5, 7 the EMBRACE protocol,10 and ICRU report #8911 that assumes that D2cc EQD2 HDR values or pulse dose rate (PDR) BT plans represent the full dose distribution (DVH) of each OAR reasonably well.…”
Section: Resultsmentioning
confidence: 99%
“…Yao et al. explored the use of gEUD as an inverse optimization objective function 45. The D2cc EQD2 OAR values are used as OAR plan evaluation metrics based upon the recommendations of the GEC‐ESTRO working group,5, 7 the EMBRACE protocol,10 and ICRU report #8911 that assumes that D2cc EQD2 HDR values or pulse dose rate (PDR) BT plans represent the full dose distribution (DVH) of each OAR reasonably well.…”
Section: Resultsmentioning
confidence: 99%
“…The index gEUD is also used in an optimization model for cervical cancer. 93 In both these HDR BT studies, the objective function used is the gEUD formulation 21 proposed in the context of IMRT. Equation (14) shows this formulation using the notation given in Tables II and VII.…”
Section: E1 Eud Modelsmentioning
confidence: 99%
“…Furthermore, it is observed that overdosage of the tumor has only a small impact on the gEUD, while it is very sensitive to underdosing of the tumor. 93 There has been a larger interest in optimization models based on gEUD in IMRT, possibly because nonlinear models are more common in IMRT, while linear models such as the LPM and the DVM are more common in HDR BT.…”
Section: E1 Eud Modelsmentioning
confidence: 99%
“…A more homogeneous dose distribution with respect to COIN is also obtained. The index gEUD is also used in an optimization model in [112]. In both these BT studies, the objective function used is the gEUD formulation that was proposed in the context of IMRT in [110].…”
Section: Radiobiological Modelsmentioning
confidence: 99%
“…Equation (3.7) shows this formulation using the notation given in Table 3.6. Survival probability of the tumour cells, with t = 0 it gives the initial probability Furthermore, in [112] it is observed that overdosage of the tumour has only a small impact on the gEUD while gEUD is very sensitive to underdosing of the tumour. In IMRT there has been a larger interest in the optimization models based on gEUD, possibly because non-linear models are more common in IMRT, while linear models, such as the LPM and the DVM, are more common in HDR BT.…”
Section: Radiobiological Modelsmentioning
confidence: 99%