2018
DOI: 10.1109/tsg.2017.2690681
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Sizing, Siting and Operation of Custom Power Devices With STATCOM and APLC Functions for Real-Time Reactive Power and Network Voltage Quality Control of Smart Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
34
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
3
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(40 citation statements)
references
References 23 publications
0
34
0
Order By: Relevance
“…In [39], a survey of the literature is presented on the optimal allocation of a D-STATCOM in a distribution network. The real-time control of multiple custom power devices (CPDs) using STATCOM and active power line conditioner (APLC) [37]. In this strategy, two particle swarm optimisation (PSO) algorithms are implemented to obtain the optimal sizing/siting and online control of multiple CPDs.…”
Section: Challenges Of Implementing Dg Unitsmentioning
confidence: 99%
“…In [39], a survey of the literature is presented on the optimal allocation of a D-STATCOM in a distribution network. The real-time control of multiple custom power devices (CPDs) using STATCOM and active power line conditioner (APLC) [37]. In this strategy, two particle swarm optimisation (PSO) algorithms are implemented to obtain the optimal sizing/siting and online control of multiple CPDs.…”
Section: Challenges Of Implementing Dg Unitsmentioning
confidence: 99%
“…Moreover, these techniques require more time (one cycle) than time-domain methods to calculate Fourier coefficients, reference currents, and voltage signals for the sampling of variable coefficients. Meanwhile, time-domain techniques use instantaneous p-q theory [160], synchronous d-q reference frame theorem [161], synchronous detection theorem [120,162], constant power factor algorithm [163], PI controller [156], fuzzy controller [164], hysteresis controller [165], and sliding-mode controller [166]. Methods such as dividing frequency control [167] and extension p-q theorem [168] are implemented to generate the reference signals, which implement the p-q technique.…”
Section: Apfs/statcom Control Techniquesmentioning
confidence: 99%
“…The maximal amount of reactive power output must respect always the active power demand of the LV grid and the size of MV converter of ST. The reactive power availability can be evaluated as (2).…”
Section: B Smart Transformermentioning
confidence: 99%
“…Thanks to the development of power semiconductors and cost reductions, it is more common to install the power electronics-based devices in grid. The functionalities of this kind of devices such as STATCOM and SVC, to support power grid operation by reactive power injection/absorption, have been analysed widely [2]- [6]. With these functionalities, the grid operation can satisfy the safety limits within an acceptable margin.…”
Section: Introductionmentioning