Optimal sensor placement for leak localization in water distribution networks based on a novel semi-supervised strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…The concentration of sensors in the lowest pressure zone of this network can be observed. This zone is also the one identified as the most sensitive by Equation (1). The use of the conditional entropy provides a more widespread distribution of sensors (see Figure 6).…”
Section: Case Studymentioning
confidence: 92%
See 1 more Smart Citation
“…The concentration of sensors in the lowest pressure zone of this network can be observed. This zone is also the one identified as the most sensitive by Equation (1). The use of the conditional entropy provides a more widespread distribution of sensors (see Figure 6).…”
Section: Case Studymentioning
confidence: 92%
“…Optimal sensor placement (OSP) for leakage detection in water distribution networks (WDNs) currently represents an exciting and lively field of research, aimed at optimising processes of network control, management, and maintenance [1].…”
Section: Introduction and Literature Reviewmentioning
confidence: 99%
“…Figure 4a shows the volume of water flow in the five zones of the water supply network. The minimum daily flow volume usually occurred between 1:00 a.m. and 6:00 a.m. Li et al 21 set the lowest hourly coefficients of nodal demands in EPANET from 5:00 a.m. to 6:00 a.m. and 6:00 p.m. to 8:00 p.m. The instantaneous minimum flow in zone 1 was 0.004 m 3 /min at 5:32 a.m., that in zone 2 was 0.085 m 3 /min (including water from zone 1) at 5:22 a.m., that in zone 3 was 0.158 m 3 /min (including water from zones 1 and 2) at 4:42 a.m., that in zone 4 was 0.594 m 3 /min (including water from zones 1, 2, and 3) at 2:16 a.m., and that in zone 5 was 0.785 m 3 /min (including water from zones 1, 2, 3, and 4) at 3:59 a.m. (Figure 4b).…”
Section: Resultsmentioning
confidence: 99%
“…There are four pressure sensors and they are marked with red dots in the Fig. 9 (Li Et al.,2019). Each pipe in the network was analyzed, for the pipe section with poor positioning accuracy, they are marked with blue in Fig .…”
Section: Case2mentioning
confidence: 99%