2015
DOI: 10.11591/telkomnika.v14i2.7605
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Placement of Phasor Measurement Unit for Better Power System Observability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…As comparison and to make the network are observable at all buses provide the power system network with less number of PMUs [20], in this paper another method used To reduce number of PMUs based optimization approach is introduced by using Integer Linear Programming in [21], its work to PMUs placement and give the number of PMUs when the operation condition is normal. As shown in Table 8.…”
Section: Comparison and Analysis Approachmentioning
confidence: 99%
“…As comparison and to make the network are observable at all buses provide the power system network with less number of PMUs [20], in this paper another method used To reduce number of PMUs based optimization approach is introduced by using Integer Linear Programming in [21], its work to PMUs placement and give the number of PMUs when the operation condition is normal. As shown in Table 8.…”
Section: Comparison and Analysis Approachmentioning
confidence: 99%
“…Phasor-measurement-units (PMUs) can generate synchronized measurements of real-time voltage and current phasor, which are highly important and desirable to power engineers. 1 It has only lately become technically feasible to synchronize measurements from several places, which has made it impossible to detect the phase-angle of bus-voltage in real-time. However, The power system's use of PMUs has made it feasible to measure the voltages and currents' real-time phasor based on GPS clock at numerous remote locations.…”
Section: Introductionmentioning
confidence: 99%
“…Phasor‐measurement‐units (PMUs) can generate synchronized measurements of real‐time voltage and current phasor, which are highly important and desirable to power engineers 1 . It has only lately become technically feasible to synchronize measurements from several places, which has made it impossible to detect the phase‐angle of bus‐voltage in real‐time.…”
Section: Introductionmentioning
confidence: 99%
“…Providing selected buses with PMUs can make the entire system observable. The authors in [9,10] developed an optimal placement algorithm for PMUs by using integer linear programming. Moreover, modeling of zero injection buses has been presented in [10].…”
Section: Introductionmentioning
confidence: 99%
“…The authors in [9,10] developed an optimal placement algorithm for PMUs by using integer linear programming. Moreover, modeling of zero injection buses has been presented in [10]. In reference [11], a generalized integer linear programming formulation and solution approach for placement of PMUs is proposed.…”
Section: Introductionmentioning
confidence: 99%