Optimal design of controllers and harmonic compensators for three-level cascaded control in stationary reference frame for grid-supporting inverters-based AC microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(3 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…A hybrid optimization system refers to a combination of different optimization algorithms or techniques such as p-metaheuristic, s-metaheuristic, machine learning, and mathematical programming that are integrated to improve algorithm efficiency, reduce search time, provide better quality solutions, improve effectiveness, provide accuracy, and solve complex optimization problems [42][43][44][45][46][47][48][49][50] . Exploration and exploitation are typically the two different phases of the process in metaheuristic optimization.…”
Section: Proposed Hybrid Optimization Systemmentioning
confidence: 99%
“…A hybrid optimization system refers to a combination of different optimization algorithms or techniques such as p-metaheuristic, s-metaheuristic, machine learning, and mathematical programming that are integrated to improve algorithm efficiency, reduce search time, provide better quality solutions, improve effectiveness, provide accuracy, and solve complex optimization problems [42][43][44][45][46][47][48][49][50] . Exploration and exploitation are typically the two different phases of the process in metaheuristic optimization.…”
Section: Proposed Hybrid Optimization Systemmentioning
confidence: 99%
“…The main core of the developed control structure for the suggested energy management system is a PI regulator. In the presented research, the Integral Absolute Error (IAE), Integral Square Error (ISE), Integral Time Absolute Error (ITAE), and Integral Time Square Error (ITSE) are chosen as performance indices to accomplish the tuning process [39][40][41][42][43][44]. The most significant results with the number of iterations (itr), objective function (Obj.…”
Section: Harris Hawks Optimization-based Energy Management Schemementioning
confidence: 99%
“…Regardless of the method used to limit the current, all of them aim to limit the total current, without discriminating between the different current components of this current. With this regard, the limitation of the AHF capability in case of VSC overload has been previously explored in current controllers for active power filters: saturation approaches [37], [38], virtual impedance techniques [39] and optimization algorithms [40]. However, the limitation of the AHF capability in case of VSC overcurrent with direct harmonic voltage tracking remains unexplored.…”
Section: Introductionmentioning