2016 International Conference on Circuit, Power and Computing Technologies (ICCPCT) 2016
DOI: 10.1109/iccpct.2016.7530251
|View full text |Cite
|
Sign up to set email alerts
|

Optimal control of islanded microgrid with adaptive fuzzy logic & PI controller using HBCC under various voltage & load variation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 10 publications
0
3
0
1
Order By: Relevance
“…The anti‐islanding protection of the PV inverter will be triggered and disconnected from the network when the voltage and frequency of the islanded network exceed the boundary of Non‐detection Zone (NDZ) for a short duration as stated in the standards. The boundary for the NDZ is set in accordance with Malaysia standards, MS 1873 as shown in Figure …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The anti‐islanding protection of the PV inverter will be triggered and disconnected from the network when the voltage and frequency of the islanded network exceed the boundary of Non‐detection Zone (NDZ) for a short duration as stated in the standards. The boundary for the NDZ is set in accordance with Malaysia standards, MS 1873 as shown in Figure …”
Section: Methodsmentioning
confidence: 99%
“…The boundary for the NDZ is set in accordance with Malaysia standards, MS 1873 as shown in Figure 5. 31 The NDZ as illustrated in Figure 5 depicts the boundary of NDZ of a PV inverter where over-frequency and underfrequency are fixed at 50.5 and 49.5 Hz respectively whereas the over-voltage and under-voltage are at 253.0 and 216.2 V respectively. For continuous operation of PV inverter, voltage and frequency have to be within the NDZ which is the grey region in Figure 5.…”
Section: Non-detection Zone Of Pv Invertermentioning
confidence: 99%
See 1 more Smart Citation
“…Outra combinação de estratégias realizada com o modulador de histerese, foi proposta através de simulação computacional e utilizando-se do Software Mathlab em [61] e combina a histerese com os controladores PI e a conhecida Lógica Fuzzy, estabelecendo os limites máximos de corrente para a segurança da estrutura em semiponte, sem isolamento, do VSI utilizado. A relação entre a corrente do indutor e a tensão de saída pode ser encontrada por [29]:…”
Section: Histerese Com Largura De Banda Variávelunclassified