1989
DOI: 10.1016/0030-4018(89)90327-1
|View full text |Cite
|
Sign up to set email alerts
|

Optically pumped lasers from Na2 D 1Πu state

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

1991
1991
2006
2006

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…In a second step, in order to determine frequencies for transitions that cover both X 1 + g (up to v = 62) and B 1 u (up to v = 33) states up to dissociation, our results were combined with previous data from the literature. In this sense, we have incorporated into the current analysis the energy terms between v = 46 and 62 reported by Barrow et al [23] and Babaky and Hussein [24] for the X 1 + g state, and between v = 30 and 33 for the B 1 u excited state reported by Vedder et al [29] and Richter et al [31]. Small typographical mistakes in T 46,15 = 5514.3496 cm −1 and T 52,15 = 5824.7242 cm −1 were corrected from table I of [23].…”
Section: Excitationmentioning
confidence: 99%
See 4 more Smart Citations
“…In a second step, in order to determine frequencies for transitions that cover both X 1 + g (up to v = 62) and B 1 u (up to v = 33) states up to dissociation, our results were combined with previous data from the literature. In this sense, we have incorporated into the current analysis the energy terms between v = 46 and 62 reported by Barrow et al [23] and Babaky and Hussein [24] for the X 1 + g state, and between v = 30 and 33 for the B 1 u excited state reported by Vedder et al [29] and Richter et al [31]. Small typographical mistakes in T 46,15 = 5514.3496 cm −1 and T 52,15 = 5824.7242 cm −1 were corrected from table I of [23].…”
Section: Excitationmentioning
confidence: 99%
“…Small typographical mistakes in T 46,15 = 5514.3496 cm −1 and T 52,15 = 5824.7242 cm −1 were corrected from table I of [23]. Also in [23,24] the Y 20 , Y 11 and Y 00 Dunham coefficients should be negative in sign. With regard to the information included in the fits, lines with differences in wavenumber greater than 0.20 cm −1 with respect to the calculated values obtained from Dunham coefficients reported by Kusch and Hessel [27] (for fluorescence series within their analysis range) were not considered in the current analysis.…”
Section: Excitationmentioning
confidence: 99%
See 3 more Smart Citations