1999
DOI: 10.1366/0003702991946541
|View full text |Cite
|
Sign up to set email alerts
|

Optical Spectroscopic Method for in vivo Measurement of Cardiac Myoglobin Oxygen Saturation

Abstract: A fiber-optic-based spectrophotometer was developed to acquire optical reflectance spectra from a living dog heart. A bullseye concentric optical probe with a 3 mm source-to-detector fiber separation was designed to obtain a 1.5 mm average tissue depth of light penetration. Spectra were analyzed in the near-infrared region from 660 to 840 nm. Myoglobin oxygen saturation was determined by partial least-squares analysis using a calibration spectral data set developed in vitro. Comparison of in vivo and in vitro … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
49
0

Year Published

2001
2001
2011
2011

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(50 citation statements)
references
References 23 publications
(23 reference statements)
1
49
0
Order By: Relevance
“…In muscle tissue, absorption by static objects (i.e. not blood) was approximated with a 0.6 % myoglobin content (Jansson and Sylvén 1983) (assuming a 76.3 % water content in muscle (Bergstrom, Furst et al 1974)), oxygenized to 90 % (Schenkman, Marble et al 1999a). Myoglobin absorption data was compiled from Bowen (1949), Millar, Moss et al (1996) and Shenkman, Marble et al (1999b).…”
Section: Tissue Modelsmentioning
confidence: 99%
“…In muscle tissue, absorption by static objects (i.e. not blood) was approximated with a 0.6 % myoglobin content (Jansson and Sylvén 1983) (assuming a 76.3 % water content in muscle (Bergstrom, Furst et al 1974)), oxygenized to 90 % (Schenkman, Marble et al 1999a). Myoglobin absorption data was compiled from Bowen (1949), Millar, Moss et al (1996) and Shenkman, Marble et al (1999b).…”
Section: Tissue Modelsmentioning
confidence: 99%
“…The interpretation and understanding of alveoli-blood or blood-tissue gas exchange, whether being assessed from the observations of arterial and venous O 2 concentrations, 20,51,54 or by intra-tissue chemical signals such as BOLD MRI 46,53 or hemoglobin and myoglobin spectra, 59,60 or by external detection of tracer content such as 15 O-oxygen and 15 O-water through PET studies, 27,51,55,62 depends in general on all the factors involved in the dissociation of oxyhemoglobin. To study the dynamics of O 2 transport and metabolism, it is therefore important to account for the transport and exchange of CO 2 , , and H + as well as O 2 -CO 2 interactions.…”
Section: Introductionmentioning
confidence: 99%
“…There could be several reasons for this discrepancy. First, Hb is absent from the sample and Mb may remain partially oxygenated even at very low PO 2 [16] and [31]. Second, the epicardial contamination by the oxygen from the surrounding air is significant for very small hearts [32].…”
Section: -D Imaging Of Tissue Oxygenation In a Rodent Heart With A Mmentioning
confidence: 99%
“…These changes can be detected in the visible and near infrared (NIR) spectral range. Previously, oxygen-dependent changes of Mb in intact myocardium have been detected by visible-NIR point spectroscopy in rodent and swine hearts [12], [13], [14], [15], [16] and [17] and NIR spectroscopic imaging (NIRSI) in swine hearts [18] and [19]. The depth of NIR light penetration into the tissue can reach several mm [19].…”
Section: Introductionmentioning
confidence: 99%