1968
DOI: 10.1103/physrev.166.751
|View full text |Cite
|
Sign up to set email alerts
|

Optical Properties of Cd-O and Zn-O Complexes in GaP

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

1969
1969
1981
1981

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 204 publications
(27 citation statements)
references
References 12 publications
0
27
0
Order By: Relevance
“…Using the procedure implied by Eqs. (15) and (16), we get (E e -E m ) = 0.62 eV for the dominant electron level and (E e -E q ) = 1.08 eV for the dominant hole level. The latter, which could not be arrived at by any other interpretation, is consistent with a level reported from thermal-quenching measurements on HgS.…”
Section: A Mercury Sulfidementioning
confidence: 97%
See 1 more Smart Citation
“…Using the procedure implied by Eqs. (15) and (16), we get (E e -E m ) = 0.62 eV for the dominant electron level and (E e -E q ) = 1.08 eV for the dominant hole level. The latter, which could not be arrived at by any other interpretation, is consistent with a level reported from thermal-quenching measurements on HgS.…”
Section: A Mercury Sulfidementioning
confidence: 97%
“…(1) and (2) with Eqs. (13) and (14) [or (15) and (16) N q and (/xoN c ). Of course, if the intrinsic quantity JJLON C were known from independent information, then measurement of Vm would simply provide a self-consistency check.…”
Section: G G Roberts and F W Schmidlinmentioning
confidence: 99%
“…In addition, T. Morgan did extensive work on defects in GaP. In collaboration with B. Welber and R. Bhargava, he showed that red luminescence is due to cadmiumoxygen or zinc-oxygen complexes rather than pairs, as had been previously supposed [226]. With H. Maier, Morgan demonstrated the importance of strain in determining ionization energies of defects [227] and applied the analyses to the oxygen center [228].…”
Section: Defects and Defect Controlmentioning
confidence: 94%
“…7, using Eq [4]. The loss through killers is unimportant above p ----4.1017 cm -3, more so in comparison with the loss by the Auger effect.…”
Section: (14) Are Indicated By Dots Curve 3 Represents the Higher Llmentioning
confidence: 97%
“…[4] to experiment, Bo/rxl.o can be estimated at 2.5-3.8.10 -is cm ~. Assuming the low temperature value of rxro, being 107 sec -1 (6), to be applicable to GaP (Zn, O) at room temperature we obtain Bo ----2.5-3.8.10 -it cm~-sec -i.…”
Section: (14) Are Indicated By Dots Curve 3 Represents the Higher Llmentioning
confidence: 98%