Optical Monitoring and Detection of Spinal Cord Ischemia

Abstract: Spinal cord ischemia can lead to paralysis or paraparesis, but if detected early it may be amenable to treatment. Current methods use evoked potentials for detection of spinal cord ischemia, a decades old technology whose warning signs are indirect and significantly delayed from the onset of ischemia. Here we introduce and demonstrate a prototype fiber optic device that directly measures spinal cord blood flow and oxygenation. This technical advance in neurological monitoring promises a new standard of care fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
31
0

Year Published

2014
2014
2025
2025

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 35 publications
(32 citation statements)
references
References 53 publications
1
31
0
Order By: Relevance
“…The monitor, which collects blood flow (DCS) and oxygenation (DOS) data, is composed of two modules as described previously 17 . Briefly, the DCS module uses a long-coherent, continuous-wave 785 nm laser (CrystaLaser Inc., NV) as a light source.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The monitor, which collects blood flow (DCS) and oxygenation (DOS) data, is composed of two modules as described previously 17 . Briefly, the DCS module uses a long-coherent, continuous-wave 785 nm laser (CrystaLaser Inc., NV) as a light source.…”
Section: Methodsmentioning
confidence: 99%
“…We have developed a near-infrared optical device that can accurately monitor and immediately detect the occurrence of spinal cord ischemia 17 . The device is based on the principles of Diffuse Correlation Spectroscopy (DCS) and Diffuse Optical Spectroscopy (DOS), which have previously been employed successfully in research to measure cerebral hemodynamics, in cancer diagnostics, and muscle perfusion studies 18,19 .…”
Section: Introductionmentioning
confidence: 99%
“…3). In addition, DCS has been used to detect acute spinal cord ischemia in sheep models, 44 to assess CBF changes due to vocal stuttering, 45 and to elucidate the effects of normal aging on posture manipulations. 46 Per new therapeutics, DCS has been used to characterize the cerebral hemodynamic responses due to transcranial magnetic stimulation (TMS) in an effort to elucidate the mechanisms of TMS.…”
Section: Diffuse Correlation Spectroscopy Applicationsmentioning
confidence: 99%
“…NIRS estimates mixed tissue hemoglobin oxygen saturation levels of the arterial, venous, and capillary blood within the field of view [10,11], which allows the oxygen supply-and-demand balance to be evaluated under differing conditions. Similar to what has been done with the cerebrum, several studies have measured spinal cord oxygenation using NIRS directly [12][13][14][15] (via surgical procedure or thin fiber-optic probe placed in the intrathecal or epidural space) or indirectly [16][17][18][19] (via paraspinal muscle oxygenation monitoring, based on the paraspinal collateral network concept) to monitor spinal cord perfusion, but few studies to date have assessed spinal cord autoregulation using this method.…”
Section: Introductionmentioning
confidence: 99%