2001
DOI: 10.1016/s0030-3992(01)00022-6
|View full text |Cite
|
Sign up to set email alerts
|

Optical fiber sensor-based detection of partial discharges in power transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
53
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 106 publications
(56 citation statements)
references
References 16 publications
0
53
0
Order By: Relevance
“…Based on literature reports [1][2][3][4][5][6][7][8][9][10][11] it can be concluded that at an adequate regime of metrology, the optical spectrophotometry method not only enables for accurate detection of radiation generated by electrical discharges, but also for widely understood analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Based on literature reports [1][2][3][4][5][6][7][8][9][10][11] it can be concluded that at an adequate regime of metrology, the optical spectrophotometry method not only enables for accurate detection of radiation generated by electrical discharges, but also for widely understood analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Apart from AE method, there may be pointed such main methods as a spectrophotometry method based on light emission (Deng et al, 2001;Frącz et al, 2012;2013;Frącz, 2013;Wang et al, 2006), thermovision method, based on heat emission, dissolved gas analysis (DGA) method, based on chemical reactions results, electrical method, based on electrical capacitance changes, transient earth voltage (TEV), based on electromagnetic radiation in high frequency range, and ultra-high frequency (UHF) method, based on radio frequency radiation. From among all those techniques only an electrical method is a PD direct measurement method, which means it delivers exact information about testing phenomena, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Literature reports point at the following frequency bands characteristic for these phenomena: Barkhausen's acoustic eect from 10 to 65 kHz [3], magnetostriction phenomena up to 10 kHz [4], noise connected with circulation of the oil and other noises of the medium about 50 kHz [5]. Eects of these limitations are, proposed in the literature, frequency bands useful for observation of partial discharges within power transformers by means of AE method: 70 180 kHz [3,6], 100200 kHz [5], 110200 kHz [7,8] and above 500 kHz [9,10].…”
Section: Introductionmentioning
confidence: 99%