Optical fiber mercury biosensor based on immobilized urease and bromothymol blue onto the alginate-chitosan membrane in the flow-system

Abstract: An optical fiber biosensor has been developed for the detection of mercury ion based on inhibition of urease immobilized onto alginate–chitosan membrane, coupled with bromothymol blue (BTB) in the flow system. To get a good performance of the biosensor toward Hg(II) ion detection, the experimental parameters of the biosensor were optimized. Here, the maximum wavelength was detected at 580 nm, with the optimum response at pH of 6. The calibration curve had a dynamic working range at 10 to 500 μg/L of Hg(II) ion… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…The film functioned as a support material for immobilizing AgNP and AChE. Single films were made by mixing alginate hydrosol and chitosan hydrosol, as done by Hermanto et al [19]. In a petri dish, 1 μL of Tris-HCl buffer solution (pH 6.5) was added, and the mixture was stirred with a magnetic stirrer until homogeneous.…”
Section: Fabrication Of Visual Biosensormentioning
confidence: 99%
“…The film functioned as a support material for immobilizing AgNP and AChE. Single films were made by mixing alginate hydrosol and chitosan hydrosol, as done by Hermanto et al [19]. In a petri dish, 1 μL of Tris-HCl buffer solution (pH 6.5) was added, and the mixture was stirred with a magnetic stirrer until homogeneous.…”
Section: Fabrication Of Visual Biosensormentioning
confidence: 99%
“…Parameter of pH is determining aspect in the uricase-PTOL film optimizing which is changes in pH could affect sensor response sensitively. Therefore, the influence of matrix and other electrocatalytic interference can be minimized by using a buffer solution , Hermanto et al, 2022. In phosphate buffer solution containing 0.6 mM UA, the pH effect on the uricase-PTOL film response was measured at intervals of 4.0 to 9.0 (Table 1).…”
Section: Applications Of Ptol Filmmentioning
confidence: 99%
“…Working electrodes used PVC membrane and wire of Ag-AgCl while internal reference electrode (comparative electrode) utilized Ag-AgCl. Both electrodes were used in the measurement of the electromotive force (emf) (Hermanto, Mudasir, et al, 2022).…”
Section: Emf Measurementmentioning
confidence: 99%