Optical biosensor test strip for the screening and direct determination of l-glutamate in food samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
8
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 26 publications
1
8
0
1
Order By: Relevance
“…This compares favourably with a previously published value for MSG content in OXO cubes [7]. The quantity of glutamate recovered from the stock cube compares favourably with levels calculated with an optical biosensor, validated with HPLC [27] and utilising high performance thin layer chromatography [28].…”
Section: Application Of the Optimum Amperometric Biosensor (Mwcnt-chisupporting
confidence: 80%
“…This compares favourably with a previously published value for MSG content in OXO cubes [7]. The quantity of glutamate recovered from the stock cube compares favourably with levels calculated with an optical biosensor, validated with HPLC [27] and utilising high performance thin layer chromatography [28].…”
Section: Application Of the Optimum Amperometric Biosensor (Mwcnt-chisupporting
confidence: 80%
“…Various procedures were applied for the construction of biosensors such as enzyme entrapment into polymer matrix , physical adsorption by drop coating , crosslinking ,,,, layer‐by‐layer deposition , etc. The sensitivity of glutamate biosensors varied from 533 for biosensor operating at +35 °C based on GluOx covalently bound to polypyrrole‐nanoparticle‐polyaniline‐film to 0.52 μA cm −2 mmol L −1 for biosensor based on bacteria surface expressed glutamate dehydrogenase entrapped into the polyethylnediamine membrane . As seen, the characteristic analytical parameters of glutamate biosensor among the literature differs significantly as the biosensors are constructed employing different methods and they operate under divers conditions, such as potential, temperature, etc.…”
Section: Resultsmentioning
confidence: 99%
“…Thus, the determination of this compound is extremely important in both clinical and food samples. Various methods have been used to determine glutamate including high performance liquid chromatography (HPLC) ,, capillary electrophoresis , optical ,, and electrochemical techniques . Among the latter methods, a special attention is payed to electrochemical biosensors due to their sensitivity, selectivity and simple operation .…”
Section: Introductionmentioning
confidence: 99%
“…H 2 O 2 has been detected by amperometric methods [16][17] or chromogenic reaction by using flow injection system [18] or test strip [19] .…”
mentioning