Optical assay using B-doped core–shell Fe@BC nanozyme for determination of alanine aminotransferase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…ALT converts L-alanine and α-ketoglutarate into L-glutamate, and the oxidation of L-glutamate by glutamate oxidase produces H 2 O 2 , which further oxidizes 3,3′,5,5′-tetramethylbenzidine (TMB) to oxTMB by the POD-like activity of Fe@BC nanozyme, resulting in a blue-colored compound. The assay was measured in the dynamic range of 10 to 1000 U/L with a detection limit of 4 U/L [ 34 ]. Paper-based colorimetric assays for the detection of ALT and AST from various reports are summarized in Table 1 .…”
Section: Evaluation Of Hypothesis: Point-of-care Test For Diagnosis A...mentioning
confidence: 99%
“…ALT converts L-alanine and α-ketoglutarate into L-glutamate, and the oxidation of L-glutamate by glutamate oxidase produces H 2 O 2 , which further oxidizes 3,3′,5,5′-tetramethylbenzidine (TMB) to oxTMB by the POD-like activity of Fe@BC nanozyme, resulting in a blue-colored compound. The assay was measured in the dynamic range of 10 to 1000 U/L with a detection limit of 4 U/L [ 34 ]. Paper-based colorimetric assays for the detection of ALT and AST from various reports are summarized in Table 1 .…”
Section: Evaluation Of Hypothesis: Point-of-care Test For Diagnosis A...mentioning
confidence: 99%
“…The LOD of the sensor was found to be 4 U/L from the signal measured in the range of 10–1000 U/L. The results from this method were compared with the standard methods used in hospitals [ 41 ]. In another electrochemical sensing device, both ALT and AST were detected, in which the electrode was modified with pyruvate oxidase (POX) and oxaloacetate decarboxylase.…”
Section: Introductionmentioning
confidence: 99%
“…4,5 In addition to the stationary equipment in hospitals, there are many methods to detect liver function, including electrochemistry, fluorescence, and colorimetry methods. [6][7][8] Among them, electrochemistry methods have lower sensitivity and narrower detection range, fluorescence methods require expensive equipment and highly qualified operators, and colorimetry methods have greater influence on the test results from the environment. We used AST and ALT test strips for dry chemistry testing.…”
Section: Introductionmentioning