2008
DOI: 10.1111/j.1463-5224.2008.00618.x
|View full text |Cite
|
Sign up to set email alerts
|

Ophthalmic examination findings in a colony of Screech owls (Megascops asio)

Abstract: This study reports ophthalmic examination findings in Screech owls, and provide means and ranges for various ocular measurements. This is the first report of rebound tonometry and PRT in owls.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

20
118
7
18

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 91 publications
(163 citation statements)
references
References 15 publications
(29 reference statements)
20
118
7
18
Order By: Relevance
“…In birds, the main cause of decreased tear production is neurogenic related to trauma and not to dry eye syndrome, unlike what occurs in dogs (Barsotti et al 2013). In a colony of screech owls (Megascops asio), low STT values have been described and correlated with a small or even absent orbital lacrimal gland (Harris et al 2008). Therefore, to establish a standard test for lacrimal assessment in birds can be difficult due to large anatomical and physiological differences in the tear production apparatus and lacrimal drainage between species (Smith et al 2015).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In birds, the main cause of decreased tear production is neurogenic related to trauma and not to dry eye syndrome, unlike what occurs in dogs (Barsotti et al 2013). In a colony of screech owls (Megascops asio), low STT values have been described and correlated with a small or even absent orbital lacrimal gland (Harris et al 2008). Therefore, to establish a standard test for lacrimal assessment in birds can be difficult due to large anatomical and physiological differences in the tear production apparatus and lacrimal drainage between species (Smith et al 2015).…”
Section: Discussionmentioning
confidence: 99%
“…Rebound tonometer was designed for use in animals with small eyes and has recently been used in birds, such as bald eagle (21.5±1.7mm Hg) (Kuhn et al 2013), Megascops asio (11±1.9mm Hg) (Harris et al 2008), Spheniscus dermersus (31.77±3.3mm Hg) (Gonzalez-Alonso-Alegre et al 2015), Bubo bubo (10:45±1.64mm Hg) (Jeong et al 2007) and Phoenicopterus ruber ruber (9.5±1.7mm Hg) (Meekins et al 2015a). Rebound tonometer reference values overestimate IOP compared to applanation tonometry in Eurasian eagle owls (Jeong et al 2007).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4,14,15 The wide range of normal STT values in avian species justifies the importance of determining baseline values for individual species and demonstrates the risk of extrapolating normal values from one species to another. 10 The mean STT values in the present study were 16.3 6 2.5 mm/1 min when measurements from both eyes were averaged.…”
Section: Discussionmentioning
confidence: 99%
“…To our knowledge, there are no published reference values for normal IOP in western screech owls, therefore, the reference interval for normal eastern screech owls (Megascops asio) established using the TonoPen XL was used (reference interval 7-16 mm Hg). 2,3 The IOP was moderately elevated OS (37 mm Hg) but was normal OD (11 mm Hg). The ophthalmic diagnoses were anterior uveitis, ocular hypertension, and suspect pectenitis OS, along with retinitis OD.…”
Section: Clinical Reportmentioning
confidence: 99%