All Days 2011
DOI: 10.4043/22398-ms
|View full text |Cite
|
Sign up to set email alerts
|

Operational Experience of the Fatigue Performance of a Flexible Riser with a Flooded Annulus

Abstract: The integrity of BP's West of Shetland (WoS) flexible riser systems has been actively managed using a risk-based approach since they were installed in the late 90s. A failure mode that was identified as part of this process was the fatigue of armour wires in those risers with flooded annuli. Annulus flooding WoS was caused by external sheath breaches that occurred during installation and to mitigate the risks of both corrosion and corrosion fatigue, BP sealed the breach locations, displaced the sea water in th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…In this case, corrosion fatigue of armor wires may become an issue. Charlesworth et al [13] show that generally, in their stufy, the condition of both the polymer and metallic layers was good and the introduction of the corrosion inhibitor into the annulus of the pipe had a positive effect. They also present the fatigue testing program, and the S-N curves generated using the wires from the decommissioned riser are compared against curves for as-manufactured wire.…”
Section: Failure Drivers and Mechanisms Corrosionmentioning
confidence: 97%
“…In this case, corrosion fatigue of armor wires may become an issue. Charlesworth et al [13] show that generally, in their stufy, the condition of both the polymer and metallic layers was good and the introduction of the corrosion inhibitor into the annulus of the pipe had a positive effect. They also present the fatigue testing program, and the S-N curves generated using the wires from the decommissioned riser are compared against curves for as-manufactured wire.…”
Section: Failure Drivers and Mechanisms Corrosionmentioning
confidence: 97%
“…By characterisation, a marine hose is a unique type of flexible riser used in fluid transfer [10,11]. By definition, a marine hose is simply a fluid transfer conduit utilised in transferring, discharging, loading, and transporting fluids from an oil well to the platform of a floating platform or a floating structure [21][22][23]. These platforms could be an FPSO (Floating Production Storage and Offloading) vessel, a CALM (Catenary Anchor Leg Mooring) buoy, a SPAR (Single Point Anchor Reservoir), a floating semisubmersible, or a TLP (Tension Leg Platform), as depicted in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…In addition to that, corrosion also becomes an issue due to the presence of water and corrosive gasses, such as carbon dioxide (CO2) and hydrogen sulphide (H2S), which can permeate through the internal sheath into the annulus area [8][9][10][11][12]. This condition is further aggravated in the event that the external sheath is breached or damaged, allowing seawater to mix with the gas to produce a corrosive environment [2,9,13]. Considering this matter, extensive research was made in replacing the steel armour layer with composite materials which were proven to be lighter and has more resistance towards corrosion [6,7,14,15].…”
Section: Introductionmentioning
confidence: 99%