2022
DOI: 10.1016/j.applthermaleng.2022.118656
|View full text |Cite
|
Sign up to set email alerts
|

Operation optimization of the coaxial deep borehole heat exchanger coupled with ground source heat pump for building heating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…Figure 16 shows the scheme of the new hybrid h pump. Yaran Wang et al [30] found that a coaxial deep-hole ground-source heat pump obtain more heat than other types of ground-source heat pumps. At the same time, i not necessary to be concerned about environmental pollution due to the closed wa cycle.…”
Section: Building Applications For Geothermal Pump Technologymentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 16 shows the scheme of the new hybrid h pump. Yaran Wang et al [30] found that a coaxial deep-hole ground-source heat pump obtain more heat than other types of ground-source heat pumps. At the same time, i not necessary to be concerned about environmental pollution due to the closed wa cycle.…”
Section: Building Applications For Geothermal Pump Technologymentioning
confidence: 99%
“…Figure 18. The relationship between the total power consumption and the flow rates in two periods and the optimization process [30].…”
Section: Building Applications For Geothermal Pump Technologymentioning
confidence: 99%
“…At present, the research and utilization of the medium and deep GSHP systems and energy storage technology are becoming more and more mature, but there are few researches on integrating them. Wei Wang [4] established the heat transfer analytical model of closed u-well heat exchanger. And the simulation modelof the whole medium and deep ground source heat pump heating system is constructed.…”
Section: Introductionmentioning
confidence: 99%
“…In this case, the run-time and thermal loads of BHEs can be adjust to ensure their sustainable operation. Many studies (Kerme and Fung 2020;Ma et al 2020;Wang et al 2022;Zhao et al 2017) have investigated accessible strategies for reducing thermal interactions. For instance, operating a BHE intermittently provides more time for ground thermal recharge and reduces the mean ground temperature change (Arghand et al 2021;Liu et al 2016;Ma et al 2021;Yang et al 2014).…”
Section: Introductionmentioning
confidence: 99%