1997
DOI: 10.1109/28.567077
|View full text |Cite
|
Sign up to set email alerts
|

Operation of a phase locked loop system under distorted utility conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
131
0
22

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 933 publications
(153 citation statements)
references
References 2 publications
0
131
0
22
Order By: Relevance
“…The summed error between the references and sequence components of the currents of n inverter systems is minimized with (15) and (16). Minimizing the error is the same as the way of the current control working.…”
Section: Complex Optimization Problemmentioning
confidence: 99%
See 1 more Smart Citation
“…The summed error between the references and sequence components of the currents of n inverter systems is minimized with (15) and (16). Minimizing the error is the same as the way of the current control working.…”
Section: Complex Optimization Problemmentioning
confidence: 99%
“…2. This control is generally performed in the synchronous rotating dq frame in which the d axis is aligned with the positive sequence components of the terminal voltage; this alignment -socalled synchronization -is achieved with a phase-locked loop (PLL) technique [7,15]. In the synchronized frame, the active and reactive powers to the grid can be regulated by d-and q-axis current control, respectively; thus, the DClink voltage is regulated by controlling the d-axis current [16].…”
Section: Operating Characteristicsmentioning
confidence: 99%
“…A fixed frequency control suggested in [14] can maintain a stable offshore frequency and can be a potential solution for synchronization, but global positioning system (GPS) is required for each WT. In fact, for the converters used in the power system and industry, phase-locked loop (PLL) is a much simpler and more efficient tool for system synchronization [16], [17].Therefore, in this paper, a new distributed PLL-based frequency control is proposed for the operation of the WT converters connected with DR-HVDC system. Unlike in [8]-[11], communication is not required for the proposed distributed PLL-based frequency control.…”
mentioning
confidence: 99%
“…A fixed frequency control suggested in [14] can maintain a stable offshore frequency and can be a potential solution for synchronization, but global positioning system (GPS) is required for each WT. In fact, for the converters used in the power system and industry, phase-locked loop (PLL) is a much simpler and more efficient tool for system synchronization [16], [17].…”
mentioning
confidence: 99%
“…Os trabalhos de , (Milanes-Montero, et al, 2007), (Robles, et al, 2010) e (Freijedo, et al, 2009a) (Kaura, et al, 1997) e (Freijedo, et al, 2009b) tratam do ajuste do controlador do PLL.…”
Section: Montero Et Al 2007); Dual Second Order Generalized Integrunclassified