1997
DOI: 10.1109/61.634209
|View full text |Cite
|
Sign up to set email alerts
|

Operation of ±100 MVAr TVA STATCON

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
30
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 122 publications
(30 citation statements)
references
References 5 publications
0
30
0
Order By: Relevance
“…Secondly, H-bridge cascaded STATCOM is a complicated system with more In terms of current control loop, the majority of approaches associate the classic linear control method, in which the non-linear equations of the STATCOM model are linearized with a specific equilibrium. The most extensively used linear control schemes are PI controllers [9], [10]. In [9], to regulate reactive power, only a simple PI controller is lugged out.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Secondly, H-bridge cascaded STATCOM is a complicated system with more In terms of current control loop, the majority of approaches associate the classic linear control method, in which the non-linear equations of the STATCOM model are linearized with a specific equilibrium. The most extensively used linear control schemes are PI controllers [9], [10]. In [9], to regulate reactive power, only a simple PI controller is lugged out.…”
Section: Introductionmentioning
confidence: 99%
“…In [9], to regulate reactive power, only a simple PI controller is lugged out. In [10], through a decoupled control strategy, the PI controller is used in a synchronous d-q frame. However, it is hard to find the suitable parameters for designing the PI controller and the performance of the PI controller might degrade with the external disturbance.…”
Section: Introductionmentioning
confidence: 99%
“…In a distribution system, it is mainly used for voltage regulation [5]. This has a major application in weak grids, whose significant grid impedance may lead to large PCC voltage variations compared to that of strong grids.…”
Section: Introductionmentioning
confidence: 99%
“…STATCOM is the shunt-connected FACTS device that is used to provide reactive power compensation to a transmission line for solving the power quality problems [2]. By their inverter configuration, basic type of STATCOM topology can be realized by either a current-source converter (CSC) or a voltage-source converter (VSC) [3][4][5][6][7][8]. But recent research confirms several merits of CSC based STATCOM over VSC based STATCOM [9][10][11].…”
Section: Introductionmentioning
confidence: 99%