Operating limits of underexcited synchronous generator

Abstract: Standard power chart of synchronous generator has its limit defined by practical stability limit and by field current minimum in the underexcitation quadrant. However, during the time, some generators have shown certain sensitivity during the permanent underexcited operation even in the stabile operating area due to local heating of magnetic conductive parts in the end region of the machine. Underexcited operation is usually required in case of raised network voltage while the active power demands are lowered.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 4 publications
(2 reference statements)
0
2
0
1
Order By: Relevance
“…En el caso de la máxima corriente se relaciona con la corriente nominal del mencionado devanado. Al respecto de la mínima corriente tiene que ver con la operación en modo de consumo de potencia reactiva del generador [24]. Las ecuaciones que modelan el lugar geométrico de estos dos límites se indican a continuación ( )…”
Section: Generador Sincrónicosunclassified
“…En el caso de la máxima corriente se relaciona con la corriente nominal del mencionado devanado. Al respecto de la mínima corriente tiene que ver con la operación en modo de consumo de potencia reactiva del generador [24]. Las ecuaciones que modelan el lugar geométrico de estos dos límites se indican a continuación ( )…”
Section: Generador Sincrónicosunclassified
“…Electric generators have an operational limit due to the overheating of the stator windings. The end winding of the generator experiences greater heating because the magnetic flux is not axial to the core segments [1][2][3][4]. Low ventilation in this region results in lowering the machine efficiency and further wearing of the bar's isolation materials leading to a generator shutdown.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, methodology for determination of actual power chart, together with underexcited operation limits, has been defined and tested in case of 247 MVA turbogenerator ( Fig. 1) [3], [4].…”
Section: Introductionmentioning
confidence: 99%