2000
DOI: 10.1016/s0003-2670(00)00951-x
|View full text |Cite
|
Sign up to set email alerts
|

Open tubular capillary electrochromatography in fused-silica capillaries chemically bonded with macrocyclic dioxopolyamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
27
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 65 publications
(28 citation statements)
references
References 19 publications
1
27
0
Order By: Relevance
“…Therefore, preparation of the column, and particularly the stationary phase packed or immobilized on the inner walls of the capillary, is critical for CEC. The capillary columns in CEC are usually classified into three main formats [10,11,17,[26][27][28][29][30][31][32][33]: (i) packed-CEC [12][13][14][15][16][34][35][36][37][38][39][40][41], (ii) open-tubular CEC (OT-CEC) [28][29][30][31][32][42][43][44][45][46][47][48][49][50][51][52][53], and (iii) monolithic (or continuous rod) CEC [9,27,.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, preparation of the column, and particularly the stationary phase packed or immobilized on the inner walls of the capillary, is critical for CEC. The capillary columns in CEC are usually classified into three main formats [10,11,17,[26][27][28][29][30][31][32][33]: (i) packed-CEC [12][13][14][15][16][34][35][36][37][38][39][40][41], (ii) open-tubular CEC (OT-CEC) [28][29][30][31][32][42][43][44][45][46][47][48][49][50][51][52][53], and (iii) monolithic (or continuous rod) CEC [9,27,.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, a highly sensitive and selective analytical method is necessary for the simultaneous determination of the three dihydroxybenzene isomers. Up to now, various methods have been exploited for the determination of the dihydroxybenzenes, such as high performance liquid chromatography (HPLC) [3,4], spectrophotometry [5,6] Electrochemiluminescence [7], synchronous fluorescence [8], gas chromatography/mass spectrometry [9], capillary electrochromatography [10], pH-based-flow injection analysis [11], and electrochemical methods [12][13][14][15][16][17][18][19][20][21][22][23]. Among these methods, electrochemical method is of particular interest due to its high sensitivity, low cost, good selectivity, and rapid detection.…”
Section: Introductionmentioning
confidence: 99%
“…They are of great environmental concern owing to their high toxicity [4]. Various methods have been employed for the respective or simultaneous determination of them, such as spectrophotometry [5], HPLC [6], and capillary electrochromatography [7]. However, traditional spectrophotometry and colorimetric methods can be easily interfered by related compounds.…”
Section: Introductionmentioning
confidence: 99%