2017
DOI: 10.1097/imi.0000000000000392
|View full text |Cite
|
Sign up to set email alerts
|

Open: Precannulated Fenestrated Endovascular Aneurysm Repair using Guidewire Fixator

Abstract: Objective By using a guidewire fixator, the distal guidewire position can be secured in an artery. This new principle enables a method for fenestrated endovascular aortic repair where the connection between the aortic branches and the stent graft fenestrations is made before inserting and deploying the stent graft. Methods This is conducted using a fenestrated stent graft with preloaded catheters, through … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
4
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 5 publications
(5 reference statements)
0
4
0
Order By: Relevance
“…Furthermore, distal fixation allows repositioning of the proximal end of the guidewire, which can be used, e.g., during fenestrated and branched aortic repair to access angled target artery takeoff. 4 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, distal fixation allows repositioning of the proximal end of the guidewire, which can be used, e.g., during fenestrated and branched aortic repair to access angled target artery takeoff. 4 …”
Section: Discussionmentioning
confidence: 99%
“… 3 A simplistic case of a single fenestration f-EVAR in a pig model under anesthesia has been previously published. 4 …”
mentioning
confidence: 99%
“…Furthermore, distal fixation allows repositioning of the proximal end of the guidewire, which can be used, e.g., during fenestrated and branched aortic repair to access angled target artery takeoff. 4 The force of fixation tested in this study was 3 N. This force was chosen as the necessary retaining force needed to hold the guidewire during an endovascular procedure was anticipated to be limited and of this magnitude.…”
Section: Discussionmentioning
confidence: 99%
“…3 A simplistic case of a single fenestration f-EVAR in a pig model under anesthesia has been previously published. 4 Guidewire stability is also valuable in other endovascular procedures because distal fixation enables tension on the guidewire and thereby better procedure guidance, e.g., for crossover treatment of peripheral arterial disease.…”
mentioning
confidence: 99%