2015
DOI: 10.2147/opth.s78930
|View full text |Cite
|
Sign up to set email alerts
|

Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

Abstract: PurposeOpacification of hydrophilic acrylic intraocular lenses (IOLs) is an emerging complication following Descemet stripping automated endothelial keratoplasty (DSAEK). We report six cases and review the current literature.MethodsIn this retrospective, noncomparative, observational case series, patients with IOL opacification after previous DSAEK surgery were identified from corneal clinic records. Case notes were reviewed for demographic details, indication for DSAEK, IOL model, incidence of rebubbling, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 22 publications
0
16
0
1
Order By: Relevance
“…The opacified area in these cases is usually limited to a more or less circular area of the anterior optical surface, which usually corresponds to the area of the pupil and/or anterior capsulorhexis, thus to the zone of contact with the instilled air or gas, whereas parts of the IOLs covered by the capsular bag, including the haptics and the posterior optical surface, displayed no sign of opacification [ 6 11 , 13 , 15 , 16 ]. Furthermore, it appears to equally affect hydrophilic IOLs from different manufacturers (Bausch & Lomb [ 6 , 13 ], Ciba Vision [ 11 , 13 ], Lenstec [ 17 ], Oculentis [ 10 , 13 ], Rayner [ 8 , 17 ], Acri.Tec [ 16 ], Zeiss [ 18 ]). It seems, that the instillation of exogenous material into the anterior chamber and its prolonged direct contact to the IOL’s surface increases the risk of opacification of hydrophilic acrylic IOLs irrespective of the manufacturer and the exact material composition.…”
Section: Discussionmentioning
confidence: 99%
“…The opacified area in these cases is usually limited to a more or less circular area of the anterior optical surface, which usually corresponds to the area of the pupil and/or anterior capsulorhexis, thus to the zone of contact with the instilled air or gas, whereas parts of the IOLs covered by the capsular bag, including the haptics and the posterior optical surface, displayed no sign of opacification [ 6 11 , 13 , 15 , 16 ]. Furthermore, it appears to equally affect hydrophilic IOLs from different manufacturers (Bausch & Lomb [ 6 , 13 ], Ciba Vision [ 11 , 13 ], Lenstec [ 17 ], Oculentis [ 10 , 13 ], Rayner [ 8 , 17 ], Acri.Tec [ 16 ], Zeiss [ 18 ]). It seems, that the instillation of exogenous material into the anterior chamber and its prolonged direct contact to the IOL’s surface increases the risk of opacification of hydrophilic acrylic IOLs irrespective of the manufacturer and the exact material composition.…”
Section: Discussionmentioning
confidence: 99%
“…Despite the marked progress in the field of new materials and intraocular implant production technology, the incidence of IOL opacification is common. [345678910111213141516] IOL opacification is a rare but significant complication after DSAEK. The incidence of IOL opacification after DSAEK ranged from approximately 5% of 160 eyes (8 eyes)[11] to 9.7% of 154 eyes (15 eyes)[7] in a large number of patients.…”
Section: Discussionmentioning
confidence: 99%
“…Possible risk factors include an inflammatory reaction after multiple surgical procedures disrupting the blood–aqueous barrier,[4815] injection of exogenous air or gas into the AC,[61113] rebubbling after DSAEK,[10121415] and implantation of acrylic hydrophilic IOLs. [34578910111213141516]…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Of the 45 articles, five did not fulfil the inclusion criteria and were excluded from further analysis. The remaining included articles numbered 40 and were analysed using the Pierson tool …”
Section: Methodsmentioning
confidence: 99%