2017
DOI: 10.1016/j.actaastro.2017.09.007
|View full text |Cite
|
Sign up to set email alerts
|

Onsite vibrational characterization of DCMIX2/3 experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…All sensor data have been downloaded from the PIMS NASA website (https://pims.grc. of observing their specific changes (Dubert et al 2017;Ollé et al 2017).…”
Section: Vibrational Characterizationmentioning
confidence: 99%
See 1 more Smart Citation
“…All sensor data have been downloaded from the PIMS NASA website (https://pims.grc. of observing their specific changes (Dubert et al 2017;Ollé et al 2017).…”
Section: Vibrational Characterizationmentioning
confidence: 99%
“…The FFI defined in Ref. Ollé et al (2017) is a scalar indicating a logarithmic relationship between the absolute maximum of the power spectral density (PSD) of the whole frequency range with respect to the relative maximum PSD value for a predefined low frequency range. High values indicate little influence of the above mentioned low frequencies on the ongoing run.…”
Section: Vibrational Characterizationmentioning
confidence: 99%
“…This RMS highlights the oscillatory content of the acceleration signal, readily visualizing large sudden variations against the mean value or spikes. In previous works we have identified a warning spike when its RMS value exceeds 20% of the mean of all RMS values of the signal [24]. In these cases, the experimentalists should take them into account when interpreting doubtful experimental results, if any.…”
Section: Vibrational Characterizationmentioning
confidence: 95%
“…Tables 2-6, indicate the runs in which spikes were detected. The Power Spectral Density (PSD) and warning maps based on the RMS values evaluated over one-third octave frequency bands [24,25] were used. As the signals were filtered to 6 Hz, this characterization focuses on the low frequency range which it is known to be the most harmful for the thermodiffussion experiments.…”
Section: Vibrational Characterizationmentioning
confidence: 99%
“…In the framework of the European Space Agency, all campaigns of the program called "Diffusion and Thermodiffusion Coefficients Measurements in Ternary Mixtures (DCMIX)" aim to accurately measure pure diffusion, thermodiffusion and Soret coefficients of different, but technologically relevant, ternary liquid systems (Shevtsova et al 2014, Triller et al 2018 inside the International Space Station (ISS). Due to the own nature of the physical processes implied, molecular diffusion and thermodiffusion experiments take a long time, therefore, a careful monitoring of the vibrational environment is thus of capital importance to prevent spurious results potentially related to detectable disturbances occurred during the experiments (Jurado et al 2016, Ollé et al 2017, Dubert et al 2018. Based on this, the present work focused on the preliminary characterization of the DCMIX4 accelerometric environment taking into account the signals coming from the es09006 sensor, nearest to the experiment.…”
Section: Introductionmentioning
confidence: 99%