Onsite monitoring of a wall retrofitted with an external vacuum insulation composite system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…Depending on the structure of the test element, the indoor and outdoor temperature stability, and the data analysis method (either the average method for steadystate conditions or the dynamic method), the minimum duration of the test could range between 72 h and 7 days [11,30]. The data collected onsite is mostly analyzed using the average method because of its simple calculation procedures [38]. The average method and the summation method are similar to each other, specifically in terms of their simplicity and their dependency on measuring conditions.…”
Section: Heat Flow Meter Sensors For In Situ Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Depending on the structure of the test element, the indoor and outdoor temperature stability, and the data analysis method (either the average method for steadystate conditions or the dynamic method), the minimum duration of the test could range between 72 h and 7 days [11,30]. The data collected onsite is mostly analyzed using the average method because of its simple calculation procedures [38]. The average method and the summation method are similar to each other, specifically in terms of their simplicity and their dependency on measuring conditions.…”
Section: Heat Flow Meter Sensors For In Situ Measurementsmentioning
confidence: 99%
“…Gonçalves et al [38] stated that the average method would assume that the U-value of the element could be achieved by dividing the mean density of the heat flow rate by the mean environmental (ambient) temperature difference. Assuming that the index j is related to individual measurements, the U-value (W.m −2 .K −1 ) can be obtained using the following equation:…”
Section: Heat Flow Meter Sensors For In Situ Measurementsmentioning
confidence: 99%
“…Additionally, two sensors are located inside the building to measure indoor air temperature and humidity, and one sensor was placed outside the building to measure outdoor air temperature and humidity. More details about this case study are provided in Gonçalves et al [11].…”
Section: Case Studymentioning
confidence: 99%
“…Even for large surfaces, you can choose to extend a cord with the help of a spraying machine and place the insulating plates on it. The ETICS tends to have good mechanical resistance, CO 2 permeability, impermeability to water and water vapor [24], and along with these benefits, diverse studies have shown that the systems really do contribute to improving the thermal behavior of buildings [25][26][27][28][29].…”
Section: Introductionmentioning
confidence: 99%