2017
DOI: 10.1155/2017/4289517
|View full text |Cite
|
Sign up to set email alerts
|

Online Monitoring of Copper Damascene Electroplating Bath by Voltammetry: Selection of Variables for Multiblock and Hierarchical Chemometric Analysis of Voltammetric Data

Abstract: The Real Time Analyzer (RTA) utilizing DC- and AC-voltammetric techniques is an in situ, online monitoring system that provides a complete chemical analysis of different electrochemical deposition solutions. The RTA employs multivariate calibration when predicting concentration parameters from a multivariate data set. Although the hierarchical and multiblock Principal Component Regression- (PCR-) and Partial Least Squares- (PLS-) based methods can handle data sets even when the number of variables significantl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…The first objective is reached by employing for the calibration calculation methods that rely on two-way data chemometric decomposition techniques, 44 including hierarchical techniques, 48 along with multi-way methods. 49 An emphasis is put on aspects of variable selection 50 as well as transference of the master calibration analytical model calculated for the primary instrument to secondary instruments. 51 Also, methods for mitigation of adverse temperature effect on voltammograms are elaborated upon extensively.…”
Section: Plater Bath Composition Controlmentioning
confidence: 99%
“…The first objective is reached by employing for the calibration calculation methods that rely on two-way data chemometric decomposition techniques, 44 including hierarchical techniques, 48 along with multi-way methods. 49 An emphasis is put on aspects of variable selection 50 as well as transference of the master calibration analytical model calculated for the primary instrument to secondary instruments. 51 Also, methods for mitigation of adverse temperature effect on voltammograms are elaborated upon extensively.…”
Section: Plater Bath Composition Controlmentioning
confidence: 99%
“…3 Electrochemical deposition of copper interconnect technology is an essential step in 3D three-dimensional integration. 4,5 With the low electrical resistance, high resistivity to electromigration, admirable chemical, mechanical, and thermodynamic properties, the electroplating copper is an important material to fabricate the metallization layers in the damascene process. [6][7][8][9] Accelerators, inhibitors and levelers must be added to the copper electroplating bath in order to achieve a better filling effect.…”
mentioning
confidence: 99%