2017 5th International Conference on Electrical Engineering - Boumerdes (ICEE-B) 2017
DOI: 10.1109/icee-b.2017.8192117
|View full text |Cite
|
Sign up to set email alerts
|

Online model-based fault detection for grid connected PV systems monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 20 publications
(23 reference statements)
0
3
0
Order By: Relevance
“…In [22]- [27], Harrou et al and Garoudja et al parametrize the PV system through fitting the single diode model to a set of outdoor I-V measurements, and simulate the dc operating current, voltage, and power of the system. They then apply different control chart variants to monitor the difference between measured and modeled values.…”
Section: A Control Charts In the Pv System Literaturementioning
confidence: 99%
See 1 more Smart Citation
“…In [22]- [27], Harrou et al and Garoudja et al parametrize the PV system through fitting the single diode model to a set of outdoor I-V measurements, and simulate the dc operating current, voltage, and power of the system. They then apply different control chart variants to monitor the difference between measured and modeled values.…”
Section: A Control Charts In the Pv System Literaturementioning
confidence: 99%
“…They then apply different control chart variants to monitor the difference between measured and modeled values. Platon et al [19] and Livera et al [20] apply CUSUM and multivariate CUSUM charts, respectively, Ramirez and Ramiŕez [18] and Livera et al [21] apply EWMA and multivariate EWMA charts, respectively, and Harrou et al in [22] and [23] apply a combination of wavelet multiscale representation of the data and EWMA charts (dubbed MW-EWMA). The multivariate variants simultaneously monitor the current, voltage, and power residuals, thus accounting for correlations in these values, reportedly giving better detection sensitivity.…”
Section: A Control Charts In the Pv System Literaturementioning
confidence: 99%
“…Then, residuals of MPP current, voltage, and power are verified by the univariate and multivariate exponentially weighted moving average (EWMA) schemes for uncovering faults and partial shading [20]. In [21], the single one diode model and the cumulative sum (CUSUM) scheme are amalgamated to monitor the DC side of the PV system. However, detection thresholds in the previously discussed methods are computed based on the Gaussian assumption of residuals' distribution.…”
Section: Introductionmentioning
confidence: 99%