2005
DOI: 10.1081/al-200062229
|View full text |Cite
|
Sign up to set email alerts
|

OnLine Coupling of a Flow Injection System to TS‐FF‐AAS for Preconcentration and Determination of Lead in Water and Vegetables

Abstract: An online solid phase preconcentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for Pb(II) ions determination is described. In the preconcentration system, Pb(II) ions complexed with ammonium O,O-diethyl-dithiophosphate (DDTP) in an acidic medium are preconcentrated as a neutral complex onto 20 mg of polyurethane foam (PUF) packed into a mini-column. The complex retained in the PUF is then released to TS-FF-AAS by using an 80% (v/v) ethanol solution. Chemical and f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
2

Year Published

2007
2007
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 36 publications
(18 reference statements)
0
6
0
2
Order By: Relevance
“…The resulting characteristics of the obtained PUF monolithic rods offer advantages over the PUF in powder form that was used in previous works [ 20 , 30 , 31 , 34 , 35 , 36 , 38 , 40 , 42 , 45 , 51 ].…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The resulting characteristics of the obtained PUF monolithic rods offer advantages over the PUF in powder form that was used in previous works [ 20 , 30 , 31 , 34 , 35 , 36 , 38 , 40 , 42 , 45 , 51 ].…”
Section: Discussionmentioning
confidence: 97%
“…Polyurethane foam (PUF) has gained interest for use as a sorbent for lead [ 20 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ]. Many previous works have been devoted to pretreatment for the determination of lead by atomic absorption spectrometry.…”
Section: Introductionmentioning
confidence: 99%
“…Some researchers have used common sorbents such as cellulose paper , activated carbon (Quinaia et al 2006), naphthalene (Anjos et al 2007), silica modified with zirconium oxide (Macarovscha et al 2007), silica gel chemically modified with niobium(V) oxide (Dutra et al 2006), polyurethane foam (Tarley et al 2005;Santos et al 2004;Santos et al 2006b), silica gel loaded with 1,3-diaminepropane-3-propyl (de Moraes et al 2005) and Amberlite resins (Silva et al 2005a;Amorim and Bezerra 2007 (Matos and Arruda 2006), and rice husks ). Other researchers have worked with functionalization of resins, and excellent results were obtained (Cassela et al 2005;Silva et al 2004a;Lemos et al 2005).…”
Section: Preconcentration and Separation Proceduresmentioning
confidence: 99%
“…The preconcentration method precision, assessed as the relative standard deviation (n = 10) for 1.0 and 55.0 g L −1 Cd 2+ solutions, was found to be 4.04% and 2.34%, respectively. Some other parameters, such as concentration efficiency (CE) of 9.46 min −1 , consumptive index (CI) of 0.635 mL and sample throughput of 14 h −1 were determined as described in the literature [27]. The present method, when compared to previous preconcentration procedures based on solid phase extraction using MWCNT for Cd 2+ determination by FAAS (Table 3), provides low detection limit, low sample consumption and high sample throughput.…”
Section: Determination Of Analytical Characteristics and Analysis Of mentioning
confidence: 99%