2014 International Conference on Electrical Machines (ICEM) 2014
DOI: 10.1109/icelmach.2014.6960278
|View full text |Cite
|
Sign up to set email alerts
|

Online controller modifying of a six-phase induction generator in phase opening occurrences

Abstract: This study presents field oriented control of a squirrel cage six-phase induction generator (SC6PIG) when a phase fault is detected in order to minimize output power oscillations during phase opening. An unbalanced structure of squirrel cage six-phase induction machine (SC6PIM) has been modeled to analyze healthy and faulty conditions of the machine. According to the unbalanced structure of the machine, a suitable controller is defined in phase missing condition to minimize power oscillations. After fault dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…The same idea of currents averaging is discussed in papers [90,91], where the authors expand it to multiphase drives and propose their own criteria of fault detection. A similar method, which uses root mean square (RMS) values instead of averaging, was proposed in [86,87]. Calculation of square roots is a high load for the microcontroller even when using acceleration techniques [88,89], so it is desired to avoid it if possible.…”
Section: A Average Current Calculationmentioning
confidence: 99%
“…The same idea of currents averaging is discussed in papers [90,91], where the authors expand it to multiphase drives and propose their own criteria of fault detection. A similar method, which uses root mean square (RMS) values instead of averaging, was proposed in [86,87]. Calculation of square roots is a high load for the microcontroller even when using acceleration techniques [88,89], so it is desired to avoid it if possible.…”
Section: A Average Current Calculationmentioning
confidence: 99%
“…To integrate 6phase dual star induction generators in the main electricity grid, two three-phase AC/DC converters can be used, each connected with one of the stator's three-phase windings [18][19][20]. Due to the nonlinearities and multivariable structure of the associated state-space model the control and stabilization problem of 6-phase DSIGs is nontrivial [21][22][23][24]. Several attempts have been made to develop model-based control schemes for 6-phase DSIGs and to demonstrate robustness of the associated control loops to model uncertainty and perturbations [25][26][27][28].…”
Section: Introductionmentioning