2018
DOI: 10.1016/j.jtcvs.2018.03.171
|View full text |Cite
|
Sign up to set email alerts
|

One-year outcomes associated with a novel stented bovine pericardial aortic bioprosthesis

Abstract: This analysis of a new stented bovine pericardial aortic valve demonstrated low overall mortality and valve-related adverse events, and hemodynamic performance comparable to that of other surgical aortic valves.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
28
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 35 publications
(28 citation statements)
references
References 10 publications
0
28
0
Order By: Relevance
“…This is an inadvertent incorrect statement as we have previously reported comprehensive differences comparing 2dimensional transthoracic echocardiography (TTE) longaxis root measurements (diastolic leading edge to leading edge) with double-oblique CT-angiography maximum root diameters (diastolic inner wall to inner wall) in patients with BAV. 2 Indeed, we found systematic TTE underestimation of the root by 3.1 AE 2.6 mm by long-axis TTE compared with CT angiography. Therefore, we tested a new mid-diastolic short-axis 2-dimensional transthoracic root measurement method (leading edge to leading edge) ( Figure 1) and found unbiased Bland-Altman agreement between that method and CT angiography (diastolic inner wall to inner wall) for root measurement in patients with BAV.…”
Section: Prosthesis-patient Mismatch Definition(s): Let's Agree To Agmentioning
confidence: 59%
See 4 more Smart Citations
“…This is an inadvertent incorrect statement as we have previously reported comprehensive differences comparing 2dimensional transthoracic echocardiography (TTE) longaxis root measurements (diastolic leading edge to leading edge) with double-oblique CT-angiography maximum root diameters (diastolic inner wall to inner wall) in patients with BAV. 2 Indeed, we found systematic TTE underestimation of the root by 3.1 AE 2.6 mm by long-axis TTE compared with CT angiography. Therefore, we tested a new mid-diastolic short-axis 2-dimensional transthoracic root measurement method (leading edge to leading edge) ( Figure 1) and found unbiased Bland-Altman agreement between that method and CT angiography (diastolic inner wall to inner wall) for root measurement in patients with BAV.…”
Section: Prosthesis-patient Mismatch Definition(s): Let's Agree To Agmentioning
confidence: 59%
“…In their letter to the editor, Dr Durko and colleagues 1 advocated using the Valve Academic Research Consortium-2 2 adjusted criteria defining prosthesis-patient mismatch (PPM) in obese patients in the PERIGON trial of a novel aortic bioprosthesis. 3 Their letter described a high rate of PPM in PERIGON (62.6% at discharge and 75.5% at 1 year), and they speculated that this may be due to a greater proportion of obese patients being included in the trial.…”
Section: Prosthesis-patient Mismatch Definition(s): Let's Agree To Agmentioning
confidence: 99%
See 3 more Smart Citations