2020
DOI: 10.1155/2020/6340716
|View full text |Cite
|
Sign up to set email alerts
|

One-Year Clinical Outcome of Inspiron Stent in All-Comers Population (Analysis from 790 Consecutive Patients)

Abstract: Aims. The goal of this study was to evaluate the performance of the InspironTM coronary stent (Scitech Medical™, Goiás, Brazil). The InspironTM sirolimus-eluting stent uses an ultrathin L-605 cobalt-chromium alloy with a 75 μm strut thickness platform coated with an abluminal biodegradable polymer. The polymer is eliminated from the body through the tricarboxylic acid cycle in 6–9 months, releasing 80% of the drug within 30 days after its deployment. Methods. It was a prospective, single-center registry. To re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 19 publications
(2 reference statements)
0
2
0
1
Order By: Relevance
“…The L605 alloy is often used for making stents due to its excellent mechanical properties, radiopacity, and corrosion resistance 100 . Some examples of stents made from L605 are Inspiron™ coronary stent (Scitech Medical™, Goiás, Brazil) 101 and Bentley BeGrow™ stent system for newborns and infants 102 …”
Section: Manufacturing Processes Of Cocr Alloy Implantsmentioning
confidence: 99%
“…The L605 alloy is often used for making stents due to its excellent mechanical properties, radiopacity, and corrosion resistance 100 . Some examples of stents made from L605 are Inspiron™ coronary stent (Scitech Medical™, Goiás, Brazil) 101 and Bentley BeGrow™ stent system for newborns and infants 102 …”
Section: Manufacturing Processes Of Cocr Alloy Implantsmentioning
confidence: 99%
“…Registries of all-comers population demonstrated safety and excellent performance, with a low rate of adverse cardiac events. 1 , 2 In a randomized clinical trial comparing Inspiron® with Biomatrix Flex® biolimus-eluting stent, there was no difference in outcomes in patients undergoing elective or urgent percutaneous coronary intervention (PCI) after a five-year follow-up. Also, there was no stent thrombosis in patients treated with Inspiron® during the study period.…”
Section: Introductionmentioning
confidence: 99%
“…Os registros da população do tipo "all-comers" demonstraram segurança e excelente desempenho, com baixa taxa de eventos cardíacos adversos. 1,2 Em um ensaio clínico randomizado comparando Inspiron® com o stent eluidor de biolimus Biomatrix Flex®, não houve diferença nos resultados em pacientes submetidos à intervenção coronária percutânea (ICP) eletiva ou urgente após cinco anos de seguimento. Além disso, não houve trombose de stent em pacientes tratados com Inspiron® durante o período do estudo.…”
Section: Introductionunclassified