2020
DOI: 10.1039/d0ja00231c
|View full text |Cite
|
Sign up to set email alerts
|

One step sample treatment and loading using a deep eutectic solvent immobilized in a porous substrate for thermal ionization mass spectrometry of Pu(iv) ions

Abstract: A deep eutectic solvent (DES) consisting of a 2 : 1 molar mixture of undecanoic acid and tetraheptylammonium bromide was immobilized in poly(propylene) membrane for the selective preconcentration of Pu for TIMS analysis with the good analytical merits.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…To achieve a better loading performance and kinetics, various loading methods were compared to supplement the procedure for preparing the β-CD saturation solution utilized in this section. Based on current studies [18,19], the other two methods selected were ultrasound assistance and adopting the grinding method as a control, respectively. An ultrasonic wave was utilized for strengthening the loading in the former method, which resulted in a more uniform system; the IL/DES and β-CD were mixed in the solution and ultrasonicated for a sufficient duration.…”
Section: Loading Of Il/des On β-Cdmentioning
confidence: 99%
“…To achieve a better loading performance and kinetics, various loading methods were compared to supplement the procedure for preparing the β-CD saturation solution utilized in this section. Based on current studies [18,19], the other two methods selected were ultrasound assistance and adopting the grinding method as a control, respectively. An ultrasonic wave was utilized for strengthening the loading in the former method, which resulted in a more uniform system; the IL/DES and β-CD were mixed in the solution and ultrasonicated for a sufficient duration.…”
Section: Loading Of Il/des On β-Cdmentioning
confidence: 99%
“…To achieve a better loading performance and kinetics, various loading methods were compared to supplement the procedure for preparing the β-CD saturation solution utilized in this section. Based on current studies [18,19], the other two methods selected were ultrasound assistance and adopting the grinding method as a control, respectively. An ultrasonic wave was utilized for strengthening the loading in the former method, which resulted in a more uniform system; the IL/DES and β-CD were mixed in the solution and ultrasonicated for a sufficient duration.…”
Section: Loading Of Il/des On β-Cdmentioning
confidence: 99%