2021
DOI: 10.3390/tropicalmed7010005
|View full text |Cite
|
Sign up to set email alerts
|

One-Stage Hip Revision Arthroplasty Using Megaprosthesis in Severe Bone Loss of The Proximal Femur Due to Radiological Diffuse Osteomyelitis

Abstract: Managing substantial proximal and/or distal femoral bone defects is one of the biggest challenges in chronic hip periprosthetic joint infection. Most authors use two-stage arthroplasty with a temporary antibiotic-loaded cement spacer for the management of these patients. In this study, we show our experience with one-stage exchange arthroplasty in managing severe bone defects due to radiological-extensive proximal femoral osteomyelitis. Two patients were included in the study. They showed radiological-extensiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…Unfortunately, the wear particles of the polyethylene material in their articulation with the hard material can result in a reduced life span of the artificial hip joint [4][5][6]. The wear particles of polyethylene range in size between sub-micrometers to micrometers and can absorb into human bone resulting in mechanical loosening and fixation loss of implant components [7]. Ultimately, reoperation is required to correct the condition with a new hip joint prosthesis.…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, the wear particles of the polyethylene material in their articulation with the hard material can result in a reduced life span of the artificial hip joint [4][5][6]. The wear particles of polyethylene range in size between sub-micrometers to micrometers and can absorb into human bone resulting in mechanical loosening and fixation loss of implant components [7]. Ultimately, reoperation is required to correct the condition with a new hip joint prosthesis.…”
Section: Introductionmentioning
confidence: 99%
“…The present study has worked to improve implant performance in ceramic materials selection. In addition, several efforts can be made to improve implant performance, including the evaluation of ceramic-on-ceramic couplings geometry [42], adding dimples on the contact surface [43], surface finish [44], and coating/surfacing applications [45]. Surgical procedures from orthopedic doctors also affect the resistance of the total hip prosthesis after primary surgery [46].…”
Section: Ceramic-on-ceramic Couplingmentioning
confidence: 99%