2021
DOI: 10.1016/j.neuroimage.2021.118213
|View full text |Cite
|
Sign up to set email alerts
|

One-pot synthesis of carboxymethyl-dextran coated iron oxide nanoparticles (CION) for preclinical fMRI and MRA applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 138 publications
1
19
0
Order By: Relevance
“…Subjects were continuously recorded for 40 min with a dose of CNO (1 mg/kg) administered via an intraperitoneal catheter 10 min after scan onset. CBV-weighted fMRI was achieved by a bolus dose of an in-house–developed iron oxide nanoparticle (30 mg of Fe/kg, intravenously) ( 87 ). Rectal body temperatures were continuously maintained at 37° ± 0.5°C with a temperature controller (Oakton Temp9500, Cole-Parmer, Vernon Hills, IL, USA) coupled to a circulating water bath (Haake S13, Thermo Fisher Scientific, Waltham, MA, USA) that heats the MRI mouse cradle.…”
Section: Methodsmentioning
confidence: 99%
“…Subjects were continuously recorded for 40 min with a dose of CNO (1 mg/kg) administered via an intraperitoneal catheter 10 min after scan onset. CBV-weighted fMRI was achieved by a bolus dose of an in-house–developed iron oxide nanoparticle (30 mg of Fe/kg, intravenously) ( 87 ). Rectal body temperatures were continuously maintained at 37° ± 0.5°C with a temperature controller (Oakton Temp9500, Cole-Parmer, Vernon Hills, IL, USA) coupled to a circulating water bath (Haake S13, Thermo Fisher Scientific, Waltham, MA, USA) that heats the MRI mouse cradle.…”
Section: Methodsmentioning
confidence: 99%
“…A month after the virus microinjection, the skin was reopened to expose the skull, then the bone wax was removed and optical fibers (200 μm in diameter; NA: 0.39) were chronically implanted to coordinates 0.3 mm above the virus injection sites. We did not identify any significant size change in adult rat brains during the 1-month virus incubation before fiber implantation according to our recent study, 49 thus no re-adjustment of the coordinates for fiber implantation was applied. Four MR-compatible miniature brass screws (Item #94070A031, McMaster Carr, Atlanta, Georgia) were anchored to the skull, then the surface of the skull was covered with dental cement to seal implanted components and the wound was sutured to further protect the surgical site.…”
Section: Stereotactic Surgerymentioning
confidence: 99%
“…To untangle the GCaMP and Rhodamine spectra, mixed spectra acquired by fiber-photometry were analyzed using a spectral linear unmixing algorithm, which can effectively remove crosstalk between multicolor sensors as shown in previous studies. 42,43,49 Briefly, at any time point n, the mixed spectrum YðnÞ was modeled as E Q -T A R G E T ; t e m p : i n t r a l i n k -; e 0 0 4 ; 1 1 6 ; 6 6 8…”
Section: Fiber-photometry Spectral Unmixingmentioning
confidence: 99%
“…Next, rats were secured in a custom MRI cradle and a fiber optic patch cable (200 µm core, .22 NA, 7 m long), set to deliver blue light from a solid-state laser, was connected to the implanted fiber in each rat for optogenetic stimulation of the AI. Subsequently, rats were positioned in the MRI bore, anatomical scans were completed, then a functional scan was acquired during which the CBV contrast agent Feraheme (30 mg/kg intravenous) was administered to augment detection sensitivity and measure CBV-weighted signal changes (41,(79)(80)(81). Finally, rats were switched to a well-established sedation protocol combining low dose (0.5%) isoflurane with a cocktail of intravenous dexmedetomidine (0.05 mg/kg/hr) and pancuronium (0.5 mg/kg/hr), and allowed 30 minutes for their physiological parameters to stabilize before optogenetic-fMRI scanning.…”
Section: Preparation Of Rats For Fmri Scanningmentioning
confidence: 99%