1953
DOI: 10.1063/1.1721254
|View full text |Cite
|
Sign up to set email alerts
|

On the Zr-Hf System

Abstract: Wet chemical etching studies of Zr and Hf-silicate gate dielectrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
4
0

Year Published

1977
1977
2023
2023

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 56 publications
(7 citation statements)
references
References 0 publications
3
4
0
Order By: Relevance
“…The lattice parameter obtained for Hf 2 Pt at room temperature was a = 12.467(2) Å , in good agreement with that of 12.461 Å reported by Nevitt and Schwartz [18] for a sample of composition Hf 70 Pt 30 . The lattice parameters obtained for a-Hf of a = 3.1796(3) and c = 5.0696(4) A agree reasonably well with those reported by Russell [20] of a = 3.1964 and c = 5.0511 Å for a-Hf with 3% Zr, indicating that little if any Pt is incorporated in the a-Hf phase at room temperature.…”
Section: Hfptsupporting
confidence: 78%
“…The lattice parameter obtained for Hf 2 Pt at room temperature was a = 12.467(2) Å , in good agreement with that of 12.461 Å reported by Nevitt and Schwartz [18] for a sample of composition Hf 70 Pt 30 . The lattice parameters obtained for a-Hf of a = 3.1796(3) and c = 5.0696(4) A agree reasonably well with those reported by Russell [20] of a = 3.1964 and c = 5.0511 Å for a-Hf with 3% Zr, indicating that little if any Pt is incorporated in the a-Hf phase at room temperature.…”
Section: Hfptsupporting
confidence: 78%
“…Fig. 3-a shows that the Hf powder was hexagonal, in accordance with the 638559 file in the FIZ Karlsruhe-ICSD database [40]. Two extra diffraction peaks were assigned to the phenolic resin in which the milled powder was embedded, confirmed by a resin-only diffraction measurement.…”
Section: Laboratory Xrd Characterisationsupporting
confidence: 67%
“…Similarly, we computed DMC total energies for various volumes of a Hf hcp unit cell with the ratio of c/a fixed at the experimental value of 1.58. 69 We generated trial wavefunctions with DFT calculations using LDA and GGA XC functionals on a 12 × 12 × 12 k-point mesh for k-point convergence using the hcp primitive unit cell. We also performed a finite-size analysis for the DMC result of bulk hcp Hf by twist-averaging DMC total energies over total 64 twists to reduce the one-body finite size effect.…”
Section: B Pseudopotentials Validation and Verificationmentioning