Abstract: The performance of three different confluent jets ventilation (CJV) supply devices was evaluated in a classroom environment concerning thermal comfort, indoor air quality (IAQ) and energy efficiency. The CJV supply devices have the acronyms: high-momentum confluent jets (HMCJ), low-momentum confluent jets (LMCJ) and low-momentum confluent jets modified by varying airflow direction (LMCJ-M). A mixing ventilation (MV) slot jet (SJ) supply device was used as a benchmark. Comparisons were made with identical set-u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 46 publications
0
7
0
Order By: Relevance
“…In the present study, the supply device was a circular duct (0.25 m diameter and 2 m long) mounted 0.05 m below the ceiling level which had 57 nozzles on each side (d = 0.028 m) placed in three rows with 19 nozzles each. The configuration of each side can be seen in Figure 1, the spacing between columns was 3 jet diameters and the spacing between the top and bottom rows was 1 jet diameter, see [33] for more details, shown in Figures 1 and 2. Supply device nozzles can be fitted with caps that block the nozzles.…”
Section: The Studied Supply Devicesmentioning
confidence: 99%
See 3 more Smart Citations
“…In the present study, the supply device was a circular duct (0.25 m diameter and 2 m long) mounted 0.05 m below the ceiling level which had 57 nozzles on each side (d = 0.028 m) placed in three rows with 19 nozzles each. The configuration of each side can be seen in Figure 1, the spacing between columns was 3 jet diameters and the spacing between the top and bottom rows was 1 jet diameter, see [33] for more details, shown in Figures 1 and 2. Supply device nozzles can be fitted with caps that block the nozzles.…”
Section: The Studied Supply Devicesmentioning
confidence: 99%
“…The study was performed in a climate chamber (7.2 × 4.2 × 2.7 m 3 ) at the University of Gävle in Sweden, representing a typical conference room environment. The climate chamber is versatile and has previously been used to investigate different indoor environments, e.g., open-plan offices [17,41], classrooms [33][34][35]47], and small offices [15,48].…”
Section: Test Facilitiesmentioning
confidence: 99%
See 2 more Smart Citations
“…Here, we provide a brief review of the articles [7][8][9][10][11][12][13][14] published in the Special Issue. A graphical summary of the key areas covered in the Special Issue is shown in Figure 2.…”
Section: A Brief Review Of the Articles In The Special Issuementioning
confidence: 99%