2019
DOI: 10.1016/j.jfluchem.2019.01.008
|View full text |Cite
|
Sign up to set email alerts
|

On the synthesis, optical and computational studies of novel BODIPY-based phosphoramidate fluorescent dyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 48 publications
0
4
0
Order By: Relevance
“…After a mathematical correction of the data set, a simple linear equation was established in order to achieve a reasonable precision and accuracy. This simple correction procedure is a common method used throughout the literature and allows to estimate absorption 0-0 peak position with quick and low cost calculations [ 18 , 38 , 49 ]. The resulting sought equation is placed inside Figure 5 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…After a mathematical correction of the data set, a simple linear equation was established in order to achieve a reasonable precision and accuracy. This simple correction procedure is a common method used throughout the literature and allows to estimate absorption 0-0 peak position with quick and low cost calculations [ 18 , 38 , 49 ]. The resulting sought equation is placed inside Figure 5 .…”
Section: Resultsmentioning
confidence: 99%
“…From all these previous investigations, the main conclusion is that the methodology that requires the least resources in material science and biomedical research is the application of an empirical correction: “ fudge ” [ 18 , 38 , 49 ]. Fudge methods generally consist in applying an empirical correction to calculated data to make them fit with experimental results.…”
Section: Introductionmentioning
confidence: 99%
“…BODIPY fluorophores are also particularly popular in bioimaging and sensing applications due to their near unitary fluorescence quantum yield [34][35][36]. However, like most organic dyes, their small Stokes shift (10-20 nm) limits the signal-to-noise ratio due to reabsorptions of emitted photons and cross-talk between the excitation source and the fluorescent emission.…”
Section: Introductionmentioning
confidence: 99%
“…However, the use of toxic BF 3 ·OEt 2 in open air may be disadvantageous for large-scale reactions. Recently, Pedroso’s group adopted the same method to synthesize a new meso -pentafluorophenyl-BODIPY dye using CHCl 3 for LAG …”
Section: Mechanochemical Synthesis Of Conventional Dyesmentioning
confidence: 99%