2005
DOI: 10.1016/j.fluid.2005.05.021
|View full text |Cite
|
Sign up to set email alerts
|

On the measurement of individual ion activities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
45
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 48 publications
(47 citation statements)
references
References 49 publications
2
45
0
Order By: Relevance
“…In both cases, even with the correction term set to zero, one gets a reasonable measure of the real activity coefficients of the species. As discussed elsewhere, the reason for this negligible effect on ionic activities of the value assumed for the junction potential is that deviations from its true value cancel out, to a large extent, due to the calibration of the ISE response (Rodil and Vera, 2003;Wilczek-Vera and Vera, 2005;WilczekVera et al, 2006aWilczekVera et al, , 2006b. Understandably, without computers it was not easy in the past to assert the insensitivity of the ionic activity values to the value of the junction potential.…”
Section: General Considerations On the Measurability Of Activitiesmentioning
confidence: 99%
See 4 more Smart Citations
“…In both cases, even with the correction term set to zero, one gets a reasonable measure of the real activity coefficients of the species. As discussed elsewhere, the reason for this negligible effect on ionic activities of the value assumed for the junction potential is that deviations from its true value cancel out, to a large extent, due to the calibration of the ISE response (Rodil and Vera, 2003;Wilczek-Vera and Vera, 2005;WilczekVera et al, 2006aWilczekVera et al, , 2006b. Understandably, without computers it was not easy in the past to assert the insensitivity of the ionic activity values to the value of the junction potential.…”
Section: General Considerations On the Measurability Of Activitiesmentioning
confidence: 99%
“…The three unknowns are the activity coefficient of the cation, the activity coefficient of the anion, and the numerical value of E J. As discussed previously (Wilczek-Vera and Vera, 2005;Wilczek-Vera et al, 2006a) and emphasized below, one interesting case is that of homoionic measurements of KCl solutions, for which Eq (3) is too sensitive to small changes in the values of the activity coefficients of the ions while the values of the ionic activities are quite insensitive to the value of the junction potential E J.…”
Section: Measurement Of the Activities Of The Cation And The Anion Ofmentioning
confidence: 99%
See 3 more Smart Citations