2020
DOI: 10.3390/s20205810
|View full text |Cite
|
Sign up to set email alerts
|

On the Long-Period Accuracy Behavior of Inductive and Low-Power Instrument Transformers

Abstract: The accuracy evaluation of instrument transformers is always a key task when proper control and management of the power network is required. In particular, accuracy becomes a critical aspect when the grid or the instrumentation itself is operating at conditions different from the rated ones. However, before focusing on the above non-rated conditions, it is important to fully understand the instrument transformer behavior at rated conditions. To this end, this work analyzed the accuracy behavior of legacy, indu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 26 publications
(25 reference statements)
0
5
0
Order By: Relevance
“…For example, a new method for an online compensation of the temperature effect is presented in [ 28 ] for electronic ITs (EITs). The accuracy behavior over time of low-power ITs (LPITs) is studied in [ 29 ]. Finally, in [ 30 ] the metrological characterization of a calibration system aimed at testing inductive ITs over temperature is described.…”
Section: Influence Quantitiesmentioning
confidence: 99%
“…For example, a new method for an online compensation of the temperature effect is presented in [ 28 ] for electronic ITs (EITs). The accuracy behavior over time of low-power ITs (LPITs) is studied in [ 29 ]. Finally, in [ 30 ] the metrological characterization of a calibration system aimed at testing inductive ITs over temperature is described.…”
Section: Influence Quantitiesmentioning
confidence: 99%
“…Even newly modernized power stations are widely installed due to their reliability and relatively low cost. Distortion of current and voltage in the power grids causes new requirements regarding operation and transformation accuracy [1][2][3][4][5][6]. Higher harmonics in current may cause inappropriate electricity billing of active and reactive power.…”
Section: Introductionmentioning
confidence: 99%
“…Transformation of distorted current by the CT is an abnormal operating condition. However, to fully evaluate its accuracy, the behavior in the rated conditions should be first analyzed in detail [4]. Therefore, many research activities are focused on developing the methods and conditions and measuring setups to perform the wideband accuracy tests [8][9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Consequently, such quantities are tackled in the literature. For example, the effect of temperature and how to treat/compensate is studied in [ 16 , 17 , 18 ]. Humidity has been recently studied by authors in [ 19 ].…”
Section: Introductionmentioning
confidence: 99%