On the Issue of Standardizing Concrete Frost Resistance to Ensure the Reinforced Concrete Structures Durability

Abstract: When erecting monolithic reinforced concrete structures, the structure of concrete can differ significantly from the laboratory standard due to the complexity of providing favorable conditions for hardening, and therefore the compressive strength and especially the frost resistance of concrete may not meet the design requirements, which can negatively affect the reinforced concrete structure durability and require amplification, especially in earthquake-prone areas [1, 2]. Increasing the durability of reinforc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(10 citation statements)
references
References 5 publications
0
0
0
Order By: Relevance
“…In tab. 1 shows the formulas that allow to obtain the values included in the f. (1) at any time of formation of the structure for the SCC and ordinary concrete [4,14]. Table 1.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In tab. 1 shows the formulas that allow to obtain the values included in the f. (1) at any time of formation of the structure for the SCC and ordinary concrete [4,14]. Table 1.…”
Section: Methodsmentioning
confidence: 99%
“…Used during the manufacture of SCC, high-performance superplasticizers (SP), usually based on polycarboxylate ethers can also influence not only on the quantitative values of deformation indicators and the pattern of their change over time, but also on the formation of the tensile and compressive strength of concrete [5][6][7][8][9][10][11]. Also mineral additives introduced in the SCC [6,[12][13][14][15][16][17]19] can influence on creep and shrinkage. SP can increase the creep coefficient of concrete up to 30%, in some cases up to -3.5 times.…”
Section: Introductionmentioning
confidence: 99%
“…PC-1, PC-2, PC-3 -cements in combination, respectively, with RP-3, RP-4, RP-5; GOSTextrapolated data according to GOST 10178; N -according to G.V. Nesvetaev for plaster solutions from DM; B -according to data [11] for FGC with an organo-mineral modifier It is obvious from the presented data in Table . 1 and Fig. 1: -the dependence Rf = f (R) does not depend on the type of cement, dosage and type of RPP, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…., Desov A.E., Mailyan R.L., Moshchansky N.A., Kaprielov S.S., Karapetyan K.S., Kalashnikov V.I., Krasnov A.M., Powers T, Nekrasov V. V., Nesvetaev G.V., Ramanchadran V., Ulitsky I.I., Felman R., Tsilosani Z.N., Sheikin A.E. et al [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%