2019
DOI: 10.1016/j.electacta.2019.135000
|View full text |Cite
|
Sign up to set email alerts
|

On the impedance response of interdigitated electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 41 publications
1
15
0
Order By: Relevance
“…It should also be noted that the ohmic impedance obtained after subtraction of the interfacial impedance from the total impedance is complex and might be approximated by the Havriliak and Negami equation . Similarly, the rectangular, recessed, and interdigitated electrodes display frequency dispersion in a very limited high-frequency region. Orazem et al .…”
Section: Definition and Meaning Of The Cpementioning
confidence: 99%
See 1 more Smart Citation
“…It should also be noted that the ohmic impedance obtained after subtraction of the interfacial impedance from the total impedance is complex and might be approximated by the Havriliak and Negami equation . Similarly, the rectangular, recessed, and interdigitated electrodes display frequency dispersion in a very limited high-frequency region. Orazem et al .…”
Section: Definition and Meaning Of The Cpementioning
confidence: 99%
“…It should also be noted that the ohmic impedance obtained after subtraction of the interfacial impedance from the total impedance is complex 24 and might be approximated by the Havriliak and Negami equation. 25 Similarly, the rectangular, 26 recessed, 27 and interdigitated 28 electrodes display frequency dispersion in a very limited high-frequency region. Orazem et al 29 also discovered that the process of the nonuniform mass transfer to rotating disk electrode and charging of the electrode−solution interface cannot be a priori separated and lead to high-frequency frequency dispersion that resembles pseudo-CPE behavior.…”
mentioning
confidence: 99%
“…Each design featured a 2 × 3 nano-sensor array and totally six differently sized capacitors were designed (as shown in Table 1). The thickness of the nano-sensor was ∼300 nm, and IDE sensor dimensions (based on [23]) are shown in Table 1.…”
Section: B Design Of the Idementioning
confidence: 99%
“…Indeed, numerous pieces of research highlighting the development of an IDEAs-based biosensor with various detection methods have been extensively reported [ 24 , 25 , 26 ]. Enhanced signal amplification allowing detection of low-concentration bioanalytes displayed by an IDEAs-based biosensor proved to be advantageous for electrochemical biosensing [ 27 , 28 , 29 ]. With an IDEA configuration, the limit of detection (LOD) of a biosensor can be significantly improved [ 30 ].…”
Section: Introductionmentioning
confidence: 99%