1999
DOI: 10.1076/vesd.32.2.199.2087
|View full text |Cite
|
Sign up to set email alerts
|

On the Design and Development of a Magneto-Rheological Mount

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2002
2002
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(26 citation statements)
references
References 4 publications
0
26
0
Order By: Relevance
“…The constructive models presented in Refs. [95][96][97][98][99][100][101][102][103][104][105][109][110][111][112][113][114][115] are most varied and correspond to the actual directions of applications considered by the researchers. Fig.…”
Section: Dampersmentioning
confidence: 99%
See 1 more Smart Citation
“…The constructive models presented in Refs. [95][96][97][98][99][100][101][102][103][104][105][109][110][111][112][113][114][115] are most varied and correspond to the actual directions of applications considered by the researchers. Fig.…”
Section: Dampersmentioning
confidence: 99%
“…[95][96][97][98][99][100][101][102][103][104][105]. Protection against vibrations and mechanical or/and seismic shocks is being achieved using fixed dampers in active or/ and semi-active mode.…”
Section: Dampersmentioning
confidence: 99%
“…Systems such as a semi-actively controlled electrorheological (ER) #uid damper have been realized [14], which have shown promising performance potential to achieve control of end-stop impacts. Other semi-active dampers based upon magnetorheological (MR) #uids have also been developed for primary and secondary vehicle suspensions [15], where modulation of the damping force is achieved through variations in #uid viscosity caused by the applied current. These dampers can o!er considerable potential to realize variable damping with minimal time delay and minimal power consumption.…”
Section: Introductionmentioning
confidence: 99%
“…Ahn et al evaluated the performance of a designed magnetorheological mount [1]. The transmissibility of the open and closed valve condition are illustrated in Fig.…”
Section: Hardware In the Loop Testsmentioning
confidence: 99%
“…Ahn et al designed one of the earliest magnetorheological mount. The mount uses inertia track in a conventional hydraulic mount as the valve that opens or closes the MR fluid flow from upper chamber to the lower chamber and it works as the flow mode [1]. Ha et al presents a squeeze mode type MR mount.…”
Section: Introductionmentioning
confidence: 99%